Power-Circle Vulnerability Assessment and Two-Stage IPSO-Based Multi-STATCOM Allocation for Fine Voltage Regulation in Distribution Networks
Jie Zhang, Yujie Du, Yonfei Ma, Junjie Xia, Xuan Wang, Qiuyang Li, Zhibin Hu, Yulong Qiao,
Key points
From the paper's conclusion- A two-stage improved particle swarm optimization (IPSO) framework is proposed for multi-STATCOM siting and sizing in radial distribution networks, together with a power-circle external-tangency margin for independent electrical-vulnerability assessment.
Abstract
A two-stage improved particle swarm optimization (IPSO) framework is proposed for multi-STATCOM siting and sizing in radial distribution networks, together with a power-circle external-tangency margin for independent electrical-vulnerability assessment. The power-circle margin is formulated from branch active- and reactive-power circle relationships, aggregated by the arithmetic mean of incident-branch margins to avoid topological-degree bias, and cross-checked against Q–V continuation-power-flow results and load-level sensitivity. STATCOM planning minimizes the annual cost of active-power losses, annualized device investment, and operation and maintenance under hard voltage constraints. In the first optimization stage, two installation locations and coarse capacities are searched jointly; the second stage fixes the selected locations and continuously refines the capacities. On the IEEE 33-bus system, the power-circle and Q–V rankings show a Spearman correlation of 0.8644 and 90% Top-10 overlap. Deterministic enumeration identifies Bus 7 with 3.6689 Mvar as the best single-STATCOM solution, whereas the optimal dual configuration is 0.5583 Mvar at Bus 16 and 1.1571 Mvar at Bus 30. The dual solution reduces annual cost by 38.86% relative to the optimal single-device solution and reduces active-power loss to 0.1402 MW while satisfying all normal-operation voltage limits. Across 30 independent runs on the dual-device problem, the proposed IPSO attains the highest location-pair and global-solution success rates (33.33%) and the lowest mean objective value among six compared algorithms. Under restored N − 1 contingencies, the normal-operation economic optimum improves post-contingency voltage performance but is capacity-limited; with the locations fixed, a total rating of 6.5693 Mvar is required to satisfy all 31 restorable contingencies, revealing the trade-off between normal-operation economy and post-contingency voltage compliance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cost-Optimal Coordination of PV Generation and D-STATCOM Control in Active Distribution NetworksSci · 2026
- Equal-Budget Benchmarking of Metaheuristics for Joint Placement and Sizing of Distributed Generation and FACTS Devices in Transmission Networks under Renewable UncertaintyEngineering Research Express · 2026
- Reactive Power Optimization of DG-Integrated Active Distribution Network Based on an Improved Multi-Objective Particle Swarm OptimizationEngineering Research Express · 2026
- Multi-objective-optimal placement of distributed generators using adaptive optimization engaging with voltage stability indicatorJournal of Engineering and Applied Science · 2026
- Simultaneous photovoltaic distributed generation and capacitor optimization for enhancing performance indices of radial power distribution systemScientific Reports · 2025
- Reliability-oriented optimal planning of photovoltaic distributed generation and energy storage in radial distribution networksResults in Engineering · 2026