Dynamic Performance Assessment of a PEMFC-Assisted Ground Source Heat Pump System with Cascade Waste Heat Recovery in Severe Cold Regions
Xupeng Qi, Huijie Huang, Fankang Meng
Key points
From the paper's conclusion- These results demonstrate that PEMFC waste heat recovery can serve not only as an auxiliary heating source but also as an active ground thermal compensation mechanism, thereby improving the long-term thermal sustainability and operational performance of GSHP systems in severe cold regions.
Abstract
Ground source heat pump systems are prone to long-term ground thermal imbalance in severe cold regions because seasonal heat extraction considerably exceeds summer heat rejection. To address this issue, this study proposes a proton exchange membrane fuel cell-assisted ground source heat pump system with cascade waste heat recovery for a heating-dominated industrial building in Changchun, Northeast China. A TRNSYS-based dynamic simulation model was developed by coupling the building load, PEMFC stack, vertical ground heat exchanger, water-source heat pump, thermal storage tank, battery storage, circulation pumps, and coordinated control modules. The recovered PEMFC waste heat was preferentially used for space heating and thermal storage and was further allocated for ground-side thermal compensation when required. Annual and ten-year simulations were conducted to evaluate the effects of PEMFC integration on ground-side temperature, soil thermal balance, heat pump power consumption, and seasonal coefficient of performance. The simulated annual heating and cooling demands were 516,721 and 99,538 kWh, respectively, confirming the strongly heating-dominated load profile of the case building. Compared with the reference GSHP system, the PEMFC-assisted system reduced the annual soil temperature drop from 1.24 °C to 0.37 °C. Over ten years, the final average soil temperature increased from 7.29 °C to 9.95 °C, corresponding to a 52.1% reduction in cumulative soil temperature decline. In addition, the winter heat pump power range decreased from 15.76–39.94 kW to 12.33–28.90 kW, while the average heating-season COP increased from 4.68 to 5.21. These results demonstrate that PEMFC waste heat recovery can serve not only as an auxiliary heating source but also as an active ground thermal compensation mechanism, thereby improving the long-term thermal sustainability and operational performance of GSHP systems in severe cold regions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility analysis of geothermal energy utilization in ultra-low temperature district heating networks: Effect of heat distribution in underground tunnelsRenewable Energy · 2026
- Super-long gravity heat pipe system for simultaneous heating and cooling in geothermal sites with non-linear temperature gradientsEnergy · 2026
- Economic comparison of borehole field regeneration options in a cold climateE3S Web of Conferences · 2026
- High-Temperature Water-to-Water Heat Pumps for the Retrofit of a Residential ComplexBuildings · 2026
- Finite-Element Analysis of Borehole Heat Exchangers under Heating Operation: Parametric Study and Nanofluid Assessment for a GSHP System in TurinJournal of Physics: Conference Series · 2026
- Experimental validation of a fuel cell-based tri-generation system with active heat recovery for greenhouse: HeatingCase Studies in Thermal Engineering · 2026