Processes

Numerical and Experimental Analysis of Power Reflection and Thermal Homogeneity in a Continuous Flow Microwave Heater for Liquid Foods

Giovanna M. B. Hipólito, Marcella Cassares, Eduardo V. S. Pouzada, Jorge A. W. Gut

Key points

From the paper's conclusion
  • Cavity showed excellent impedance matching with an experimental power reflection of 1% without external tuning.

Abstract

A continuous flow microwave heater with a hexagonal cavity (2450 MHz) and a helical tube with 5.5 turns was experimentally and numerically analyzed for the heating of green coconut water (GCW) and a simulated fruit juice/pulp (viscous, pseudoplastic) to pasteurization temperatures. The phenomena of electromagnetism, heat transfer, and laminar flow were coupled in a multiphysics model that was numerically solved using the finite element method. Simulations showed that secondary flow and a larger power absorption in the first half of the tube improved thermal homogenization along it. The polygonal shape of the cavity provided a more disperse and uniform electric field distribution in comparison with circular and elliptical geometries. Experiments were performed at 1.0 L/min with two power levels (3.0 and 4.2 kW). Cavity showed excellent impedance matching with an experimental power reflection of 1% without external tuning. Absorption energy efficiency (magnetron to fluid) was 89 ± 3% for GCW and 96 ± 6% for the model food. Regarding homogeneity at the outlet, a temperature deviation of only 0.2 °C was predicted and measured for the GCW. For the model food, actual deviations were higher (2.2 and 4.2 °C) due to the viscosity, but acceptable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Numerical and Experimental Analysis of Power Reflection and Thermal Homogeneity in a Continuous Flow Microwave Heater for Liquid Foods — Science Skim