Resilient Control Strategies for Urban Energy Transitions: A Robust HRES Sizing Typology for Nearly Zero Energy Ports
Nikolaos Sifakis
Technical University of Crete
Key points
From the paper's conclusion- The proposed typology provides a transferable framework for resilient and low-carbon port microgrid design under real-world operational constraints.
Abstract
Ports located within dense urban environments face a major challenge in achieving deep decarbonization without compromising the reliability and safety of critical maritime operations. This study develops and validates a resilience-oriented control and sizing typology for Hybrid Renewable Energy Systems (HRESs), supporting the transition of a medium-sized Mediterranean port toward a Nearly Zero Energy Port (nZEP). The framework integrates five years of measured electrical demand at 15 min resolution to capture stochastic load variability, seasonal effects, and safety-critical peak events. Thirty-five HRES configurations are simulated using HOMER Pro, assessing photovoltaic and wind generation combined with alternative Energy Storage System (ESS) technologies under two grid-interface control strategies: Net Metering (NM) and non-NM curtailment-based operation. Conventional Lead–Acid batteries are compared with inherently safer Vanadium Redox Flow Batteries (VRFBs), while autonomy constraints of 24 h and 48 h are imposed to represent operational resilience. System performance is evaluated through a multi-criteria framework encompassing economic viability (Levelized Cost of Energy), environmental impact (Lifecycle Assessment-based carbon footprint), and operational reliability. Results indicate that NM-enabled HRES architectures significantly outperform non-NM configurations by exploiting the external grid as an active balancing layer. The optimal NM configuration achieves a Levelized Cost of Energy of 0.063 €/kWh under a 24 h autonomy constraint, while reducing operational carbon intensity to approximately 70 gCO2,eq/kWh, corresponding to a reduction exceeding 90% relative to baseline grid-dependent operation. In contrast, non-NM systems require substantial storage and generation oversizing to maintain resilience, resulting in higher curtailment losses and Levelized Cost of Energy values of 0.12–0.15 €/kWh. Across both control regimes, VRFB-based systems consistently exhibit superior robustness and safety performance compared to Lead–Acid alternatives. The proposed typology provides a transferable framework for resilient and low-carbon port microgrid design under real-world operational constraints.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Temporal and grid-constrained performance of cold-ironing and photovoltaic generation towards nearly zero energy portsNext research. · 2026
- A marine-based hybrid renewable energy optimization framework for cost and emission reduction in nearly zero-energy portsJournal of Ocean Engineering and Marine Energy · 2026
- A Rolling-Horizon Model Predictive Control Energy Management System for Shaping the Ports of the FutureSmart Cities · 2026
- Electrification of Australian remote communities through degradation-aware techno-economic and environmental optimization of sustainable vehicle-to-home enabled hybrid renewable energy systemsApplied Energy · 2026
- Modelling Cold-Ironing Potential in High-Density Ferry Quays: A Virtual Assessment for the port of AnconaJournal of Sustainable Development Indicators · 2026
- A Decision-Support Methodology for Renewable Energy Integration, OPS Demand Estimation and Day-Ahead Energy Management in PortsApplied Sciences · 2026