Polymers

Influence of Al2O3 Filler Particle Size on Moisture Barrier Performance, Electrochemical Behavior, and Rebar-Concrete Bond of EPON 828 Coatings.

Ghulam Sarwar Chandio, Iftikhar Ahmed Channa, Ali Dad Chandio

Department of Industrial and Manufacturing Engineering, NED University of Engineering and Technology, Karachi 75270, Sindh, Pakistan. · Advanced Materials and Sustainable Environments Research Group, Department of Metallurgical Engineering, NED University of Engineering and Technology, Karachi 75270, Sindh, Pakistan.

Key points

From the paper's conclusion
  • These findings show that 100 nm alumina offers the highest combination of barrier performance and bond retention of the sizes examined, and that filler size is an important parameter for developing coatings for reinforced concrete exposed to chloride conditions.

Abstract

Epoxy coatings are widely used to protect reinforcing steel from chloride-induced corrosion but improving corrosion resistance while maintaining adequate rebar-concrete bond performance remains a key challenge. This study examines how Al2O3 filler size affects both properties in epoxy coatings on TMT rebars. Filler particles of 500, 250, and 100 nm were dispersed in EPON 828 epoxy at a fixed loading of 0.85 wt.% and applied at a thickness of 70 microns. Corrosion behavior was evaluated in 3.5% NaCl by potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), weight loss, and moisture transport by water vapor transmission rate (WVTR). Pull-out testing was used to measure bond strength, uniaxial stress to assess tensile behavior, and ATR-FTIR and SEM to assess chemical structure and morphology. Corrosion current density (Icorr) decreased as particle size reduced, from 34.98 µA/cm2 for the bare sample to 5.27 µA/cm2 for 500 nm and 0.29 µA/cm2 for 100 nm coatings. Weight loss after 30 days was reduced by about 70.3% for the 100 nm coating compared to bare steel, and WVTR was reduced by 70% relative to neat epoxy. Pull-out capacity of coated bars was below that of bare steel but improved with decreasing filler size, with the 100 nm coating showing a bond reduction of about 3.5%. The tensile properties of the rebar were unaffected by coating. These findings show that 100 nm alumina offers the highest combination of barrier performance and bond retention of the sizes examined, and that filler size is an important parameter for developing coatings for reinforced concrete exposed to chloride conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Influence of Al2O3 Filler Particle Size on Moisture Barrier Performance, Electrochemical Behavior, and Rebar-Concrete Bond of EPON 828 Coatings — Science Skim