Immediate- and Extended-Release Hot-Melt Extruded Ocular Inserts for Levofloxacin Hemihydrate: Formulation Development, Optimization, and In Vitro Evaluation (Part I).
Mashan Almutairi, Ahmed Adel Ali Youssef, Gehad M Subaiea, Ahmed Alobaida, Alia Alshammari
Department of Pharmaceutics, College of Pharmacy, University of Ha'il, Ha'il 81442, Saudi Arabia. · Department of Pharmaceutics & Pharmaceutical Technology, Faculty of Pharmacy, Kafrelsheikh University, Kafrelsheikh 33516, Egypt.
Key points
From the paper's conclusion- Overall, the project outcomes prove the potential of HME for the fabrication of LFX-loaded ocular inserts with tunable release characteristics that range from immediate to extended release.
Abstract
Levofloxacin (LFX) is widely prescribed to treat bacterial ocular infections. However, its topical application as eyedrops faces rapid precorneal clearance and poor ocular surface residence. These limitations often require frequent administration. In this project, ocular inserts loaded with LFX were developed using hot-melt extrusion (HME) to address these shortcomings. A D-optimal mixture design was applied to study the effects of hydroxypropyl cellulose (HPC-JXF), polyethylene oxide (PEO-N10), and sorbitol on LFX-release behavior. Sixteen insert formulations were prepared and evaluated for their physicochemical characteristics and in vitro dissolution performance. All developed inserts showed adequate weight uniformity, thickness, surface pH, and drug content. Statistical analysis results revealed that formulation composition had a marked influence on LFX release at both 0.5 and 8 h time points. PEO-N10 played a key role in improving LFX release; however, HPC-JXF contributed to release retardation and preservation of matrix integrity. Numerical optimization identified a formulation containing 90% polymer content of HPC-JXF and 10% LFX as the optimal extended-release system. The optimized formulation released ~18% of LFX within the first 30 min and ~64% at 8 h, indicating close agreement between the experimental results and model-predicted values. Differential Scanning Calorimetry thermograms suggested that HME processing helped in the molecular dispersion of LFX throughout the polymeric carrier, resulting in an amorphous drug distribution within the insert matrix. The Korsmeyer-Peppas release exponent, determined via DDSolver modeling, indicated anomalous transport, where drug diffusion and polymer relaxation contributed to the release process. Overall, the project outcomes prove the potential of HME for the fabrication of LFX-loaded ocular inserts with tunable release characteristics that range from immediate to extended release. The optimized insert formulation could be a promising alternative platform to conventional ophthalmic eyedrops for the management of bacterial ocular infections.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Soluble ocular insert of brinzolamide and timolol maleate: in-vitro, ex-vivo and in-vivo characterization.Therapeutic delivery · 2026
- Critical Evaluation of Key Elements in Manufacturing Procedures and Testing Methodologies for Ocular Anti-Infective Thin Film Inserts.Pharmaceuticals (Basel, Switzerland) · 2026
- Optimizing topical antibiotic delivery in dogs: Tear film pharmacokinetics of moxifloxacin following pre-treatment with hyaluronic acidPLoS ONE · 2026
- Sustained Ocular Delivery of Moxifloxacin–Ufasomes-Laden In Situ Gel for Keratitis ManagementPharmaceuticals · 2026
- Mechanistic Insights and Characteristics of Levofloxacin HCl-Loaded Solvent Exchange-Triggered Myristic-Based In Situ Forming MatrixACS Omega · 2026
- High-Capacity Dexamethasone-Loaded Poly(2-Oxazoline) Micelles for Ocular Surface Applications.Biomacromolecules · 2026