Rapid Fabrication of Round Flexdym Microchannels via Direct PDMS (Thermoset)-to-Flexdym (Thermoplastic) Thermal Replication.
Md Emamul Kabir, Sonali Garg, Aldrian Muhaxheri, Paras N Prasad, Kwang W Oh
SMALL (Sensors and MicroActuators Learning Lab), Department of Electrical and Computer Engineering, University at Buffalo, The State University of New York, Buffalo, NY 14260, USA. · Department of Chemistry, University at Buffalo, The State University of New York, Buffalo, NY 14260, USA.
Key points
From the paper's conclusion- Here, we present a rapid and low-cost PDMS-to-Flexdym thermal replication strategy to directly transform round microchannel architectures from a reusable compliant thermoset PDMS mold into a thermoplastic microfluidic platform.
Abstract
Round microchannels provide physiologically relevant flow environments and improved fluidic performance compared with conventional rectangular geometries; however, their scalable fabrication in potentially biocompatible thermoplastic substrates remains challenging. Here, we present a rapid and low-cost PDMS-to-Flexdym thermal replication strategy to directly transform round microchannel architectures from a reusable compliant thermoset PDMS mold into a thermoplastic microfluidic platform. Round PDMS convex molds generated by thermal air expansion followed by PDMS double casting were used for heat-assisted conformal replication to transform spatially varying complex round microchannels into Flexdym. The method successfully transferred complex serpentine, branched, and interconnected channel architectures while preserving continuous flow paths and curved geometries. Temperature-dependent framework and experimentation revealed improved vertical feature recovery with increasing embossing temperature, while lateral dimensions remained highly conserved. Across representative channel widths of ~37-249 µm, replicated Flexdym channels achieved width and height transfer ratios of approximately 99-103% and 93-105%, respectively. Sequential dimensional analysis among concave PDMS, convex PDMS, and Flexdym replicas showed no statistically significant differences in channel width or height (p > 0.05), confirming high geometric fidelity throughout the replication process. AFM, SEM, and stylus profilometry results further verified the preservation of surface characteristics, rounded cross-sectional morphology, and reproducible channel profiles, with Flexdym surface roughness reduced from ~84.1 nm (PDMS mold) to ~25.1 nm in Flexdym after replication. Finally, integration of the replicated round channels into a multilayer microvalve demonstrated functional fluidic control through syringe-assisted compressed air actuation, supported by two-phase moving-mesh simulation and analytical air compression modeling. This strategy provides a practical route for translating PDMS-based round microchannel prototyping into scalable, more biocompatible thermoplastic microfluidic platforms for building next-generation microphysiological systems and bioengineering applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fluid-layer-assisted mold temperature control for injection-molded bridge-type compliant mechanisms: Experimental thermal validation and simulation-based benchmarking against conventional cooling channels.PloS one · 2026
- 3D Printed Microfluidic Device for Combined Thermal and Fluorescence Analysis.Microfluidics and nanofluidics · 2025
- Programmable Twisted Microchannels in Polymer Fibers via Rotational Thermal Drawing for Enhanced Micromixing.ACS applied materials & interfaces · 2026
- Agile manufacturing of PDMS microfluidic devices for cell culture without a clean roombioRxiv · 2026
- Fast multi-resolution 3D printing of microfluidics: enabling 2 μm channels and ultra-compact mixersMicrosystems & Nanoengineering · 2026
- Rapid thermoforming of polycarbonate cell culture accessories from 3D printed moldsPLoS ONE · 2026