Bayesian Two-Process Weibull Modelling of PCL-Blend-PEG Coating Degradation in Simulated Body Fluid: Composition-Held-Out Validation, Identifiability Limits and Exploratory Electrochemical Correlation.
Vlad-Cristian Stoica, Anita Ioana Visan
Independent Researcher, 031777 Bucharest, Romania. · Lasers Department, National Institute for Lasers, Plasma and Radiation Physics, 409 Atomistilor Street, Magurele, 077190 Ilfov, Romania.
Key points
From the paper's conclusion- These findings define the current predictive limits imposed by the available experimental data and provide guidance for future experimental design.
Abstract
Predicting how polycaprolactone-poly(ethylene glycol) (PCL-blend-PEG) implant coatings lose mass in simulated body fluid (SBF) would shorten costly 16-week immersion campaigns, but published studies typically provide only three to five compositions, too few for flexible data-driven models. We re-analysed the 16-week mass-loss curves of dip-coated PCL, PCL-blend-PEG 3:1, PCL-blend-PEG 1:3, and PEG films on titanium using a fully specified Bayesian workflow. A mechanistically motivated two-process Weibull model, combining a fast PEG dissolution term and a slow PCL hydrolysis term with composition-dependent time scales, was compared against a parsimonious single effective-Weibull baseline under a prespecified decision rule with exact leave-one-composition-out (LOCO) and future-time refits. Both models converged cleanly (maximum R^≤1.005, zero divergences), yet the two-process model did not outperform the baseline: pooled leave-one-composition-out mean absolute error was 43.7 percentage points for the two-process model versus 37.6 for the baseline, and pooled temporal error 13.2 versus 11.8 percentage points, respectively. The PEG parameters of the two-process model were strongly correlated (r=0.956), precluding separate identification of PEG and PCL kinetics. Empirical coverage of the nominal 90% LOCO intervals was only 21.4% for the two-process model and 3.6% for the baseline. Composition-wise, residuals localise the failure: PEG release inside blends is matrix-retarded rather than instantaneous. We report the negative result transparently, quantify the additional data needed, and release the full reproducible pipeline. These findings define the current predictive limits imposed by the available experimental data and provide guidance for future experimental design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bayesian modeling of predictive stability under generalized Arrhenius non-linear kineticsarXiv · 2026
- Interpretable Two-Stage Machine Learning for Early and Full Drug Release Prediction in PLGA MicrospheresPharmaceuticals · 2026
- Programmable in vivo degradation of PEG hydrogel microspheres through tailored crosslinker chemistry.Biomaterials science · 2026
- BMP-2 Release from Biomaterial Carriers: Reporting Heterogeneity and the Limits of Cross-Study PredictionbioRxiv · 2026
- From Molecular Structure to Human Pharmacokinetics: Clearance Prediction Drives Exposure Error in a Hybrid ML–PBPK WorkflowJournal of Chemical Information and Modeling · 2026
- Machine-Learning Versus Kinetic Models for Forecasting In Vitro Drug Release from Liposomes: A Pre-Specified BenchmarkPharmaceutics · 2026