A Flexible Wearable Multisensing Patch Integrating SWCNT-PtNPs Nanocomposites for Non-Invasive Clinical Biomarkers Monitoring in Sweat.
Lucian-Gabriel Zamfir, Petru Epure, Ioana Cătălina Gîfu, Iuliana Răut, Mariana Constantin, Cristina Firincă, Nicoleta-Olguța Corneli, Mihaela Doni,
Department of Biotechnology, National Institute for Research and Development in Chemistry and Petrochemistry-ICECHIM, 202 Spl. Independentei, 060021 Bucharest, Romania. · EPI-SISTEM SRL, Livezii 17A, 505600 Săcele, Romania.
Key points
From the paper's conclusion- Finally, a wearable patch integrating the multiplex (bio)sensor with a portable potentiostat enabled simultaneous, sensitive, and selective detection of glucose, lactate, and H2O2 in sweat samples.
Abstract
The integration of enzyme-loaded polymeric matrices with carbon-based nanomaterials and metallic nanoparticles into wearable multisensing patches, coupled with miniaturized portable detection devices, enables real-time, highly sensitive, and simultaneous monitoring of key clinical biomarkers (e.g., glucose, lactate, and H2O2) in clinical and point-of-care applications. Multiplex biosensors were fabricated by modifying screen-printed carbon paste electrodes (SPEs) with different composite nanomaterials based on carbon nanomaterials such as multi-walled carbon nanotubes (MWCNTs), single-walled carbon nanotubes (SWCNTs), or fullerenol (FL), the redox mediator Prussian Blue, and platinum nanoparticles (PtNPs). Chitosan and sol-gel polymer matrices were used to immobilize the enzymes glucose oxidase (GOx) and lactate oxidase (LOx), thus ensuring not only increased sensitivity and operational stability, but also high specificity for biomarker detection (glucose and lactate). Among the nanomaterials used for the development of multiplex biosensors, the SWCNT-PtNP composite was highlighted by electrochemical studies as having a significantly superior electrocatalytic activity toward the reduction of H2O2. This reaction occurs at a low applied potential of only -0.2 V vs. Ag/AgCl, achieving a specific sensitivity of 224.6 mA·M-1·cm-2, over a concentration range of 0.07 to 28.26 mM, and a detection limit of 3.2 μM. When functionalized with enzymes, SWCNT-PtNP-based biosensors exhibit improved conductivity, allowing the detection of glucose and lactate at a potential of -0.05 V vs. Ag/AgCl. The specific sensitivities obtained are 20.25 mA·M-1·cm-2 for glucose and 94.76 mA·M-1·cm-2 for lactate, and the corresponding detection limits are 23.6 μM and 5.0 μM, respectively. Finally, a wearable patch integrating the multiplex (bio)sensor with a portable potentiostat enabled simultaneous, sensitive, and selective detection of glucose, lactate, and H2O2 in sweat samples.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Carbon Nanotube-Based Biosensors for Non-Invasive Biofluid Analysis.Biosensors · 2026
- Wearable Foam Hydrogel Chemiluminescence Sensor for Multiplexed Sweat Analysis.Analytical chemistry · 2026
- Engineered AuNPs/fMWCNT Nanocomposite Electrodes for High‐Sensitivity Methylglyoxal Sensing in Saliva and Sweat for Non‐Invasive Diabetes MonitoringAdvanced Healthcare Materials · 2026
- Microwave-Assisted One-Pot Synthesis of Medium-Entropy Oxides for Dual-Mode Electrochemical and Colorimetric Analysis of Sweat BiomarkersAnalytical Chemistry · 2026
- Plasmon-enhanced molecularly imprinted photoelectrochemical sensor for non-invasive lactate monitoring in sweat.Chemical communications (Cambridge, England) · 2026
- Twisted carbon nanotube yarn as a metal-free microelectrode for electrochemical detection of biomolecules: Experimental and molecular-level insights.Talanta · 2026