Polymers

Enzymatic Versus Energy-Based Degradation of the Cross-Linked Hyaluronic Acid Macromolecule: A Comparative Physicochemical Study of Hyaluronidase, Focused Ultrasound and Laser Irradiation.

Anna Deda, Sławomir Wilczyński, Selin Sagbas Suner, Aneta Ostróżka-Cieślik, Anna Stolecka-Warzecha, Nurettin Sahiner

Department of Practical Cosmetology and Skin Diagnostics, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, 40-084 Katowice, Poland. · Department of Basic Biomedical Science, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Jedności Street 8b, 41-208 Sosnowiec, Poland.

Key points

From the paper's conclusion
  • These findings identify long-pulsed 1064 nm irradiation as an effective non-enzymatic route to degrade the cross-linked hyaluronic acid macromolecule, with hyaluronidase remaining the reference standard.

Abstract

Hyaluronic acid (HA) is a high-molecular-weight glycosaminoglycan whose cross-linked hydrogels are widely used as injectable fillers; their controlled degradation is clinically important but, in practice, achievable only enzymatically with hyaluronidase. Here we compared the enzymatic, ultrasonic and photothermal degradation of a single cross-linked HA macromolecular network and characterised the resulting structural, thermal and chromatographic changes. A cross-linked HA hydrogel (Regenyal Idea, 25 mg/mL) was embedded in an ex vivo porcine skin matrix and treated in six groups: untreated control; hyaluronidase; microfocused ultrasound (7 MHz, 3 mm focal depth); and irradiation with 1064 nm Nd:YAG, diode or alexandrite lasers. Degradation was characterised by FT-IR spectroscopy, thermogravimetric analysis (TGA) and high-performance liquid chromatography (HPLC). FT-IR showed retention of the HA backbone with partial loss of the cross-linked network, while TGA revealed treatment-dependent decreases in thermal stability. By HPLC, hyaluronidase released the most soluble HA (58.2 ± 2.9% at day 1; ~88% plateau by day 2). Among the energy-based methods, only the 1064 nm Nd:YAG laser produced comparable degradation (57.3 ± 5.2%), whereas microfocused ultrasound, the diode and the alexandrite lasers released little soluble HA (3.2-5.3%). The wavelength dependence is consistent with a water-mediated photothermal scission of the HA chains. These findings identify long-pulsed 1064 nm irradiation as an effective non-enzymatic route to degrade the cross-linked hyaluronic acid macromolecule, with hyaluronidase remaining the reference standard.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Enzymatic Versus Energy-Based Degradation of the Cross-Linked Hyaluronic Acid Macromolecule: A Comparative Physicochemical Study of Hyaluronidase, Focused Ultrasound and Laser Irradiation — Science Skim