Enzymatic Versus Energy-Based Degradation of the Cross-Linked Hyaluronic Acid Macromolecule: A Comparative Physicochemical Study of Hyaluronidase, Focused Ultrasound and Laser Irradiation.
Anna Deda, Sławomir Wilczyński, Selin Sagbas Suner, Aneta Ostróżka-Cieślik, Anna Stolecka-Warzecha, Nurettin Sahiner
Department of Practical Cosmetology and Skin Diagnostics, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, 40-084 Katowice, Poland. · Department of Basic Biomedical Science, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia, Jedności Street 8b, 41-208 Sosnowiec, Poland.
Key points
From the paper's conclusion- These findings identify long-pulsed 1064 nm irradiation as an effective non-enzymatic route to degrade the cross-linked hyaluronic acid macromolecule, with hyaluronidase remaining the reference standard.
Abstract
Hyaluronic acid (HA) is a high-molecular-weight glycosaminoglycan whose cross-linked hydrogels are widely used as injectable fillers; their controlled degradation is clinically important but, in practice, achievable only enzymatically with hyaluronidase. Here we compared the enzymatic, ultrasonic and photothermal degradation of a single cross-linked HA macromolecular network and characterised the resulting structural, thermal and chromatographic changes. A cross-linked HA hydrogel (Regenyal Idea, 25 mg/mL) was embedded in an ex vivo porcine skin matrix and treated in six groups: untreated control; hyaluronidase; microfocused ultrasound (7 MHz, 3 mm focal depth); and irradiation with 1064 nm Nd:YAG, diode or alexandrite lasers. Degradation was characterised by FT-IR spectroscopy, thermogravimetric analysis (TGA) and high-performance liquid chromatography (HPLC). FT-IR showed retention of the HA backbone with partial loss of the cross-linked network, while TGA revealed treatment-dependent decreases in thermal stability. By HPLC, hyaluronidase released the most soluble HA (58.2 ± 2.9% at day 1; ~88% plateau by day 2). Among the energy-based methods, only the 1064 nm Nd:YAG laser produced comparable degradation (57.3 ± 5.2%), whereas microfocused ultrasound, the diode and the alexandrite lasers released little soluble HA (3.2-5.3%). The wavelength dependence is consistent with a water-mediated photothermal scission of the HA chains. These findings identify long-pulsed 1064 nm irradiation as an effective non-enzymatic route to degrade the cross-linked hyaluronic acid macromolecule, with hyaluronidase remaining the reference standard.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hyaluronic Acid-Based Injectable Hydrogels for Dermal and Soft Tissue Engineering: From Polysaccharide Network Architecture to Structure–Property–Function RelationshipsPolysaccharides · 2026
- Hyaluronan Hydrogels: Three Material States in Regenerative Orthopaedics.Gels (Basel, Switzerland) · 2026
- Integrated mechanical and structural characterisation of 24 commercial hyaluronic acid fillers: A multi-parametric framework for comparative analysisJournal of Colloid and Interface Science · 2026
- Key considerations from intrinsic properties to context-dependent performance in the preclinical evaluation of crosslinked HA dermal fillersScientific Reports · 2026
- Understanding Clinical and Biophysical Differences Between Non‐Cross‐Linked and Cross‐Linked Hyaluronic Acid Dermal FillersJournal of Cosmetic Dermatology · 2025
- Engineering a self-protecting dermal filler: active hyaluronidase inhibition extends the in vivo persistence of cross-linked hyaluronic acid hydrogels.RSC advances · 2026