Tablet Erosion Under Heterogeneous Flow in USP Apparatus II.
Una Lote Vītoliņa, Ance Bārzdiņa, Diāna Brūvere, Normunds Jēkabsons, Oskars Radziņš, Artūrs Lācis, Sabīne Upnere, Baiba Mauriņa,
Department of Applied Pharmacy, Riga Stradins University, 21 Konsula Str, LV-1007 Riga, Latvia. · Institute of Physics, University of Latvia, 3 Jelgavas Str, LV-1004 Riga, Latvia.
Key points
From the paper's conclusion- Conclusions: Post-dissolution tablet shape complements dissolution profiles by revealing the spatial distribution of material loss and may serve as a complementary approach to assessing local hydrodynamic heterogeneity in USP Apparatus II.
Abstract
Background/Objectives: Although hydrodynamic heterogeneity in USP Apparatus II has been extensively studied, few experimental studies have examined how it affects the dosage form. This study investigated how paddle rotation speed, radial tablet position, and bottom-surface exposure affect dissolution and post-dissolution erosion patterns of paracetamol model tablets, and whether residual tablet shape provides complementary information on local hydrodynamic heterogeneity. Methods: Two paracetamol model tablet types were used: model tablets (MT) for visualization of post-dissolution shape by micro-computed tomography and photography, and MT with an embedded steel washer (SW-MT) for height measurements. SW-MT dissolution was tested at 25-75 rpm at 0D, 0.5D, and 1D positions, with and without bottom-surface coating, and evaluated using the fraction dissolved after 40 min (Q40), while height changes were quantified using erosion height loss (EH) and height asymmetry (AH). Computational fluid dynamics (CFD) results aided erosion-pattern interpretation. Results: Increasing paddle rotation speed increased dissolution and erosion extent, whereas radial displacement affected erosion distribution. At 0D, residual MT shapes were comparatively symmetrical, while 0.5D and 1D produced pronounced erosion patterns. Greater erosion extent did not correspond to greater asymmetry: for uncoated SW-MT at 75 rpm, EH increased from 36% at 0.5D to 40% at 1D, whereas AH decreased from 19% to 9%. Directional erosion in MT was consistent with spatial differences in velocity and predicted surface erosion rate from CFD. Conclusions: Post-dissolution tablet shape complements dissolution profiles by revealing the spatial distribution of material loss and may serve as a complementary approach to assessing local hydrodynamic heterogeneity in USP Apparatus II.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Biopredictive Fed-State Dissolution Method Incorporating High-Viscosity Media and Hydrodynamic Stress.Pharmaceutics · 2026
- Image-Based Quantification of Amorphous Solid Dispersion Tablet Formulation Disintegration Profiles in a Custom USP-2 Apparatus.Molecular pharmaceutics · 2026
- Computational fluid dynamics-based modeling of drug dissolution in non-Newtonian media.International journal of pharmaceutics · 2026
- Hydrodynamic Cavitation-induced Breakage of Carbamazepine Dihydrate Crystals: Experimental Insights and ModelingIndustrial & Engineering Chemistry Research · 2025
- Dissolution coning in USP apparatus II - Part I: quantifying formulation-dependent coning severity with the drug entrapment fraction (DEF).International journal of pharmaceutics · 2026
- Particle erosion wear in a high-pressure homogenizer – insights from DPM-CFD-erosion modellingWear · 2025