Pharmaceuticals (Basel, Switzerland)

Molecular Attribution and Assay Replacement Readiness of Multi-Attribute Methods in Biosimilar Development.

Shruthi Sunderrajan, Suranjana Haldar, Santosh Kumar Palanirajan, Srikanth Jandhyam, Anita Krishnan

Research and Development, Biocon Biologics Limited, Bengaluru 560099, India.

Key points

From the paper's conclusion
  • We evaluated MAM integration and replacement readiness in two IgG1 biosimilar programs.

Abstract

Background/Objectives: Multi-attribute method (MAM) provides early molecular attribution in biosimilar development, but assay replacement requires separate evidence. We evaluated MAM integration and replacement readiness in two IgG1 biosimilar programs. Methods: Conventional charge and released-glycan profiles of US-licensed and EU-approved reference product (RP) lots were compared with site-specific MAM measurements. Carboxypeptidase B (CpB) treatment, orthogonal species characterization, intact-mass analysis, and evaluation across alternative analytical configurations were used to assess attribution, coverage, and replacement readiness. Results: MAM assigned specific contributors within conventional charge and glycan profiles, whereas intact methods retained information beyond monitored attributes. For mAb-Cys, 5-7 percentage points of the acidic cation exchange chromatography (CEX) region remained unassigned, and candidate hinge-clipped and non-native disulfide species could not be quantified as contributors to RP residuals. In both molecules, MAM C-terminal lysine values were approximately twice the per-chain occupancy implied by CpB-responsive CEX measurements, demonstrating that peptide- and intact-level measurements are not numerically interchangeable. Across analytical configurations, C-terminal lysine was consistently quantifiable, but reported levels differed; glycan-class reporting depended on processing software whereas deamidation depended on both software detection and chromatographic separation. Common-software reprocessing enabled full-panel quantitation in the evaluated datasets. Conclusions: MAM should be integrated early to provide molecular attribution, but attribution alone does not establish assay replacement readiness. Replacement requires three evidence pillars: (1) reconciliation with conventional measurements and coverage of relevant process-related species, (2) MAM-specific RP distributions, and (3) complete attribute coverage with fit-for-purpose performance on the intended integrated analytical configuration.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Molecular Attribution and Assay Replacement Readiness of Multi-Attribute Methods in Biosimilar Development — Science Skim