Detachable Modular Blood-Brain Barrier-on-a-Chip with a Concentration Gradient Generator for Stepwise Inflammation Modeling and Drug Evaluation.
Zezhi Li, Haizhu Meng, Xinmeng Liao, Shuqi Wang, Dan Hu, Lijuan Chen, Yuanhang Chang, Junwei Zhao,
Beijing Life Science Academy, Building 1, Courtyard 7, Yingcai South 1st Street, Changping District, Beijing 102209, China. · First Clinical Medical College, Shandong Medical and Pharmaceutical University, No. 318, Gangcheng East Street, Laishan District, Yantai 264003, China.
Key points
From the paper's conclusion- Conclusions: The detachable modular design makes multi-step inflammation modeling and gradient-based anti-inflammatory evaluation convenient on a single chip; QUER’s consistent advantage over KAE across binding calculations and functional assays supports a structure-activity relationship consistent with ICAM-1 engagement.
Abstract
Background/Objectives: The blood-brain barrier (BBB) is compromised in many neurological disorders, yet in vitro models rarely reproduce graded inflammatory stimulation of brain endothelial cells in vivo. This study developed a detachable, modular BBB-on-a-chip for stepwise inflammation modeling with multi-marker readout, and compared the anti-inflammatory efficacy of quercetin (QUER) and kaempferol (KAE). Methods: The chip combines a Christmas-tree concentration gradient generator with a four-channel culture module, fabricated separately and assembled on demand for stepwise seeding, exposure, dosing, and sampling. hCMEC/D3 cells were exposed to a TNF-α gradient (0-30 ng/mL); extracellular ATP, ROS, NO, cytokines, ZO-1, and ICAM-1 were monitored over 48 h. Transcriptomics and network pharmacology were integrated with molecular docking and 100 ns molecular dynamics simulations; QUER and KAE were administered gradient-wise (0-20 μM), with dexamethasone as a control. Results: The TNF-α gradient induced time- and concentration-dependent injury, with ATP and IL-8 responding at 8 h, ROS and NO at 12 h, and IL-1β, IL-6, and tight-junction impairment later, yielding spatiotemporally resolved readouts across four parallel channels. Ten hub inflammatory genes, including ICAM1, were identified, and network pharmacology nominated QUER. QUER was predicted to bind ICAM-1 more strongly than KAE, its structural analog differing by one B-ring hydroxyl group; gradient administration confirmed QUER suppressed ICAM-1 expression and inflammatory mediator release at lower concentrations. Conclusions: The detachable modular design makes multi-step inflammation modeling and gradient-based anti-inflammatory evaluation convenient on a single chip; QUER's consistent advantage over KAE across binding calculations and functional assays supports a structure-activity relationship consistent with ICAM-1 engagement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Establishing a Microfluidic Co-Culture Blood-Brain Barrier Model Using Human Brain Endothelial Cells and Astrocytes.Journal of visualized experiments : JoVE · 2026
- An Integrated Experimental-Computational Platform for Evaluating Blood-Brain Barrier Permeability of Novel Kynurenic Acid Derivatives.European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences · 2026
- Engineering the blood–brain barrier on chip: advances in preclinical drug penetration and disease modelingAdvanced Drug Delivery Reviews · 2026
- Ultrasound-Controlled Blood-Brain Barrier (BBB) Opening in a BBB-Glioblastoma Microfluidic Chip for Drug Delivery Studies.Journal of visualized experiments : JoVE · 2026
- Microenvironment-Driven 3-Dimensional Biofabrication Enables Sequential Maturation of the Blood-Brain Barrier.Research (Washington, D.C.) · 2026
- Lab-on-a-chip device integrating a human stem cell-based blood-brain barrier model with neural organoids for translational researchbioRxiv · 2026