Laboratory-Acquired Yersinia pestis Infection: Occupational Exposure, Clinical Presentation and Microbiological Identification.
Salma Elnour Rahma Mohamed, Sara Mohamed Ali, Sara Rahma, Sara Mohamed Osman
Department of Medical Laboratory Sciences, College of Health Sciences, Gulf Medical University, Ajman P.O. Box 4184, United Arab Emirates. · College of Medicine, Al-Neelain University, Khartoum P.O. Box 12702, Sudan.
Key points
From the paper's conclusion- The record that can be reconstructed in detail comprises two cases: a fatal infection reported from Chicago in 2009, in which no exposure event was identified, occupation was absent from the clinical record and the organism was identified only after death; a survived infection from a United States laboratory in 1959, in which the exposure was likewise unrecognised but the occupational context was
Abstract
Laboratory work with Yersinia pestis is governed by detailed containment provisions, and laboratory-acquired infection is rare: a scoping review covering 2000 to 2021 attributed two of 309 cases to Y. pestis. Preventing exposure and recognising infection after an unidentified exposure are, however, distinct problems, and the second has received less attention. This narrative review, supported by a documented search of PubMed, PubMed Central and major biosafety and public-health agency websites to October 2026, classified evidence into seven categories and analysed them without pooling. The record that can be reconstructed in detail comprises two cases: a fatal infection reported from Chicago in 2009, in which no exposure event was identified, occupation was absent from the clinical record and the organism was identified only after death; a survived infection from a United States laboratory in 1959, in which the exposure was likewise unrecognised but the occupational context was known at admission and the organism was identified within 18 h. Evidence from naturally acquired plague documents bidirectional misidentification of Y. pestis by commercial automated and mass-spectrometry systems, attributable to reference-library composition rather than instrument performance. Recognition therefore appears to depend on information held separately by the worker, the employing institution, the treating clinician and the clinical microbiology laboratory, while many containment and response measures become operative only once exposure or plague is suspected. Post-work health monitoring and symptom reporting are specified as requirements in Russian and Canadian national documents but appear only as recommendations in the United States guidance reviewed. These observations rest on a small case record and indicate areas for evaluation rather than an established pattern.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fatal Pasteurella multocida sepsis following cat bite in occult liver disease: a forensic pathological perspective.Forensic science, medicine, and pathology · 2026
- Plague in the modern world: Ecological persistence, epidemic containment, and the limits of public health preparedness.Bioscience trends · 2026
- Operational Challenges and Diagnostic Accuracy of Rapid Diagnostic Test and Bacterial Culture Using Quantitative PCR as the Operational Reference Standard During Routine Plague Surveillance in Ituri Province, Democratic Republic of the CongoTropical Medicine and Infectious Disease · 2026
- Biosafety of rabies virus and related lyssaviruses: Risks, precautions, and knowledge gaps in diagnostic and research laboratories.PLoS neglected tropical diseases · 2026
- Under-Recognized Melioidosis in Indonesia: Evidence of Diagnostic Misidentification in Bali.Pathogens (Basel, Switzerland) · 2026
- Laboratory Quality Management Systems and Their Impact on Diagnostic Accuracy During Infectious Disease OutbreaksInternational Journal of Scientific Research in Science and Technology · 2026