Rapid Detection of Marek's Disease Virus Using Cold-Chain-Independent Lyophilized LAMP Beads for Closed-Tube, Single-Step, Fluorometric LAMP and Penn-RAMP Assays.
Mohamed El-Tholoth, Dina Mohammed, Rabiha Seboussi
Health Sciences Division, Al Ain Zakhir Campus, Higher Colleges of Technology, Abu Dhabi 17155, United Arab Emirates. · College of Veterinary Medicine, University of AlDhaid, Sharjah, United Arab Emirates.
Key points
From the paper's conclusion- The closed-tube RAMP assay achieved a 10-fold lower limit of detection (10 genomic copies/reaction) compared to both LAMP and qPCR.
Abstract
BACKGROUND/OBJECTIVES: Marek's disease virus (MDV) is a highly contagious oncogenic virus in chickens, which causes immunosuppression and lymphoproliferative tumors leading to substantial economic losses to the poultry industry. Early, accurate and accessible detection is essential for effective disease surveillance and control. Conventional polymerase chain reaction (PCR)-based approaches are reliable for diagnosis but their reliance on expensive lab equipment and skilled operators limits their use in resource-limited and decentralized settings. The objective of this study was to develop two rapid, inexpensive, and user-friendly fluorometric isothermal amplification assays for MDV detection. METHODS: A loop-mediated isothermal amplification (LAMP) assay and a nested isothermal amplification (Penn-RAMP) assay were developed for MDV detection. Penn-RAMP assay combines recombinase polymerase amplification (RPA) at 38 °C and LAMP at 65 °C in a single closed tube. Both assays were conducted using cold-chain-free lyophilized LAMP reagent beads for simplified storage and transportation, thereby increasing their applicability for molecular diagnostics at the point of need. The performance of these assays was compared to quantitative PCR (qPCR). RESULTS: The sensitivity of the LAMP assay was 100 copies of genomic DNA per reaction. The closed-tube RAMP assay achieved a 10-fold lower limit of detection (10 genomic copies/reaction) compared to both LAMP and qPCR. The clinical performance of the developed assays showed 100% sensitivity and specificity against the qPCR. CONCLUSIONS: Our assays offer a rapid, sensitive, specific and simple method for MDV molecular diagnosis, especially for resource-limited veterinary diagnostic laboratories.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of Two Multienzyme Isothermal Rapid Amplification Techniques for the Rapid Visual Detection of Micropterus salmoides rhabdovirusJournal of Fish Diseases · 2026
- A Rapid and Sensitive Loop-Mediated Isothermal Amplification Assay for the Detection of Mulberry Mosaic Dwarf-Associated Virus.Biosensors · 2026
- A-370 MDx-in-a-Bead: scaling point-of-care diagnostics with a simplified, lyophilized LAMP frameworkClinical Chemistry · 2026
- Loop-Mediated Isothermal Amplification (LAMP) for the Diagnosis of High-Burden Viral Diseases in Resource-Limited Countries.Pathogens (Basel, Switzerland) · 2026
- Identification of MDV and REV Using RPA-CRISPR/Cas12a Combined with Fluorescence and Lateral Flow Assays.Analytical biochemistry · 2026
- A rapid and sensitive HiFi-LAMP assay for the detection of varicella-zoster virus.Diagnostic microbiology and infectious disease · 2026