Cardiovascular, Cerebral, and Performance Responses to Q-Collar™ Use in a 5 km Cycling Time Trial: A Randomized Crossover Trial
Kelsey Bourbeau, Andrew Wells, Zac Simon, Mark Hecimovich, Ben Boezinger, Issa Sullivan, Dylan Darsidan, Terence Moriarty
Key points
From the paper's conclusion- Therefore, the purpose of the study was to investigate hemodynamic, metabolic, prefrontal cortex oxygenation (PFC-O2Hb), choice reaction time (CRT) via the Stroop test, and time-to-completion outcomes with and without Q-Collar™ use.
Abstract
Background/Objectives: The Q-Collar™, a device that mildly compresses the jugular veins to increase cranial fluid volume, has been investigated for potential protection against brain changes associated with concussive and subconcussive impacts during athletic events involving physical contact. However, physiological responses using this device as well as the physical and cognitive performance outcomes remain unclear. Therefore, the purpose of the study was to investigate hemodynamic, metabolic, prefrontal cortex oxygenation (PFC-O2Hb), choice reaction time (CRT) via the Stroop test, and time-to-completion outcomes with and without Q-Collar™ use. Methods: Eleven male participants qualified for inclusion into the repeated-measures randomized crossover study following an incremental cycling cardiopulmonary exercise test. Upon qualification, participants visited the lab twice to complete a 5 km cycling time trial with and without Q-Collar™ use. Each visit was separated by at least 72 h. Results: No statistically significant differences in hemodynamic, blood lactate (BLa−), PFC-O2Hb, or time-to-completion outcomes were found comparing Q-Collar™ use to a Control condition. However, improved CRT was found during, immediately following, and 10 min post the time trial relative to a resting CRT baseline. Conclusions: No statistically significant acute differences were detected between Q-Collar™ and Control for measured outcomes during a 5 km cycling time trial in this exploratory study. Smaller effects cannot be excluded, and because jugular compression was not verified during exercise, these findings reflect the effect of wearing a manufacturer-fitted Q-Collar™ rather than verified jugular compression. CRT was shorter during and after exercise relative to rest in both conditions, although repeated-testing effects cannot be excluded.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Between-visit Reproducibility of Cerebrovascular and Cardiovascular Reactivity During the Cold Pressor Test.American journal of physiology. Heart and circulatory physiology · 2026
- Resistance‐trained young men exhibit enhanced carotid vasoreactivity during the cold pressor testExperimental Physiology · 2026
- Hidden Overshoot in Cerebral Blood Flow: Implications for Accurate Assessment of Cerebral CO2 Reactivity.American journal of physiology. Regulatory, integrative and comparative physiology · 2026
- Concordance Between a Temple-Worn Optical Wearable and Transcranial Doppler During Exercise and Postural Transitions in Healthy AdultsmedRxiv · 2026
- Cerebrovascular Responses to Aerobic Exercise in Young Healthy non-Hispanic Black and White Males.American journal of physiology. Regulatory, integrative and comparative physiology · 2026
- Short Term Effects of Football Headers on Reaction Time and Symptomology in Males and FemalesEuropean Journal of Sport Science · 2026