Fluorescent Marker Monitoring and Nurse-Led Feedback for Operating Room Environmental Cleaning: A Quasi-Experimental Single-Group Pre-Post Study.
Paulo Brois, Sofia Rita, Marco Serafim, Soraia Pereira, Fernanda Príncipe, Henrique Pereira, Liliana Mota
Clean Hospitals, 1262 Eysins, Switzerland. · Baixo Alentejo Local Health Unit, 7801-849 Beja, Portugal.
Key points
From the paper's conclusion- The approach may support nurse-led quality improvement in operating room environmental hygiene.
Abstract
Background: Environmental hygiene in operating rooms is essential for infection prevention, but visual inspection alone may not reliably identify missed cleaning. Aim: To assess the feasibility of fluorescent gel marker monitoring with ultraviolet light, combined with a nurse-led educational and feedback intervention, on the cleaning of high-touch operating room surfaces. Methods: A quasi-experimental, nonrandomized, single-group pre-post study was conducted in five operating rooms of a district general hospital in southern Portugal. Forty-two cleaning episodes and 420 surface assessments were evaluated across three sequential phases: blinded baseline monitoring, post-training monitoring after a 45-min nurse-led workshop, and feedback-based monitoring using an ultraviolet walk-through. The primary outcome was the proportion of surface assessments classified as completely clean. Exploratory Mann-Whitney U tests compared ordinal cleaning outcomes between phases; p-values were nominal and not adjusted for multiple comparisons. Results: Complete cleanliness increased from 44.7% at baseline to 69.3% after training and 89.2% during feedback-based monitoring. The largest observed increases occurred among surfaces with poor baseline performance, particularly anesthesia machine rebreathing bags, IV stands, computer keyboards, and computer mice. Visual inspection identified dust on keyboards and occasional medication residue but missed several surfaces detected by fluorescent marker assessment. Conclusions: Fluorescent marker monitoring with ultraviolet feedback was feasible within the study setting and was accompanied by progressive improvements in the proportion of surfaces classified as completely clean. However, the absence of a concurrent control group precludes attributing these changes exclusively to the intervention. The approach may support nurse-led quality improvement in operating room environmental hygiene.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fluorescent tagging for assessment of environmental cleaning in an equine hospital.Equine veterinary journal · 2026
- Improving environmental cleaning quality and consistency in a multi-campus hospital using a computer vision-assisted mobile application: a prospective interventional study.Antimicrobial resistance and infection control · 2026
- Scanner-Measured Hand Hygiene Performance After Automated Visual Feedback-Supported Training: A Multicenter Quality Improvement Project in Italian Hospitals.Nursing reports (Pavia, Italy) · 2026
- Illuminating Hand Hygiene Practice: Strengthening the Foundation to Infection Prevention in the NICU.Neonatal network : NN · 2026
- Hand hygiene training: innovating HAI prevention for future healthcare professionalsEuropean Journal of Public Health · 2026
- Environmental hygiene programs in public hospitals: a pilot study of pre-implementation assessment.American journal of infection control · 2026