Nutrient Calculation Accuracy, Expert-Rated Clinical Appropriateness and Safety Indicators, and Reproducibility of Large Language Model-Generated Diet Plans for Polyendocrine Metabolic Ovarian Syndrome: A Real-Case-Based Evaluation.
Ayşenur Çalık, Pınar Ece Demiray, Ayşe Betül Bilen, Gülen Ecem Kalkan, Muazzez Garipağaoğlu
Department of Nutrition and Dietetics, Faculty of Health Sciences, Istanbul Atlas University, Istanbul 34403, Türkiye. · Department of Nutrition and Dietetics, Faculty of Health Sciences, Fenerbahçe University, Istanbul 34758, Türkiye.
Key points
From the paper's conclusion- Background/Objectives: This study evaluated the nutrient calculation accuracy, reproducibility, and expert-rated clinical appropriateness and safety indicators of three-day diet plans generated for women with polycystic ovary syndrome (PCOS), recently proposed to be termed polyendocrine metabolic ovarian syndrome (PMOS).
Abstract
Background/Objectives: This study evaluated the nutrient calculation accuracy, reproducibility, and expert-rated clinical appropriateness and safety indicators of three-day diet plans generated for women with polycystic ovary syndrome (PCOS), recently proposed to be termed polyendocrine metabolic ovarian syndrome (PMOS). Methods: Anonymized data from six women with heterogeneous PMOS profiles, purposively selected from a single clinic, were converted into standardized Turkish prompts and submitted to ChatGPT-4, Claude Sonnet 4.6, Gemini 2.5 Flash, and Mistral 2.0 through free web interfaces. Three independent generations per case-model combination yielded 216 daily menus. LLM-reported nutrient values were compared with BeBiS 9.0 calculations. Reproducibility was assessed using intraclass correlation coefficients (ICCs). Two experts independently evaluated the first generated plan for each case-model combination using a study-specific clinical appropriateness rubric and red-flag checklist. Results: No model achieved consistently low error across nutrients. Claude Sonnet 4.6 showed the lowest percentage errors for energy, carbohydrate, and fiber; ChatGPT-4 for protein; and Mistral 2.0 for fat. Gemini 2.5 Flash showed the largest percentage errors across all nutrients and a mean energy bias of +531.1 kcal. ChatGPT-4 showed comparatively higher plan-level reproducibility, while the remaining models generally showed poor reproducibility. Claude Sonnet 4.6 had the highest descriptive clinical appropriateness scores and Gemini 2.5 Flash the lowest, but no pairwise differences remained significant after Holm correction. Gemini 2.5 Flash generated the most confirmed study-specific red flags (n = 28), with all six cases meeting the criterion for the "masked low-energy" indicator. Conclusions: LLM-generated diet plans showed model-dependent calculation errors and limited reproducibility, and the present findings do not support their independent or unsupervised use as individualized clinical nutrition recommendations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Nutritional Accuracy and Clinical Applicability of Large Language Model-Generated Therapeutic Diet Plans for Phenylketonuria: A Comparative Simulation Study.Nutrients · 2026
- Evaluating AI‐Generated Meal Plans for Simulated Diabetes Profiles: A Guideline‐Based Comparison of Three Language ModelsJournal of Evaluation in Clinical Practice · 2025
- Large Language Models as Clinical Nutrition Decision Tools: Quantitative Bias and Guideline Deviation in Type 2 Diabetes Meal PlanningHealthcare · 2026
- Artificial intelligence diet plans underestimate nutrient intake compared to dietitians in adolescentsFrontiers in Nutrition · 2026
- Large language models in food and nutrition science: Opportunities, challenges, and the case of FoodyLLMCurrent Research in Food Science · 2026
- Large Language Models for Real-World Nutrition Assessment: Structured Prompts, Multi-Model Validation and Expert OversightNutrients · 2025