Self-Templated Highly Porous Gold Electrodes for Antibiofouling Electrochemical (Bio)Sensors
Anisa Degjoni, Cristina Tortolini, Daniele Passeri, Andrea Lenzi, Riccarda Antiochia
Sapienza University of Rome
Key points
From the paper's conclusion- Here, we demonstrate the effect of a highly porous gold (h-PG) film electrodeposited on a gold screen-printed electrode (AuSPE) using a self-templated method via hydrogen bubbling as an antibiofouling strategy in electrochemical biosensor development following exposure of the electrode to bovine serum albumin (BSA) at two different concentrations (2 and 32 mg/mL).
Abstract
Biofouling arises from non-specific adsorption of several components present in complex biofluids, such as full blood, on the surface of electrochemical biosensors, with a resulting loss of functionality. Most biomarkers of clinical relevance are present in biological fluids at extremely low concentrations, making antibiofouling strategies necessary in electrochemical biosensing. Here, we demonstrate the effect of a highly porous gold (h-PG) film electrodeposited on a gold screen-printed electrode (AuSPE) using a self-templated method via hydrogen bubbling as an antibiofouling strategy in electrochemical biosensor development following exposure of the electrode to bovine serum albumin (BSA) at two different concentrations (2 and 32 mg/mL). The h-PG film has a high electrochemically active surface area, 88 times higher than the AuSPE electrode, with a pore size ranging from 2 to 50 μm. A rapid decrease in the Faradaic current was observed with the unmodified AuSPE, attesting to the strong biofouling effect of BSA at both concentrations tested. Notably, the h-PG-modified electrode showed an initial peak current decline, more evident at a higher BSA concentration, followed by rapid electrode regeneration when the electrode was left idle in the biofouling solution. Similar results were obtained for unmodified and modified electrodes in real serum and plasma samples. The regeneration process, explained in terms of balance between h-PG pore size and protein size, the nanoscale architecture of the h-PG electrodes, and repulsive electrostatic forces, indicates the huge potential of the h-PG film for use in biomedical electrochemical sensing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Applied Potential on Albumin Adsorption and Electrochemical Accessibility at Gold and Graphitic Carbon InterfacesLangmuir · 2026
- Flow-Injection Amperometric Detection of Bisphenol F Using a Hierarchical Multimodal Nanoporous Gold-Multi-Walled Carbon Nanotube Modified Screen-Printed ElectrodeChemosensors · 2026
- A Superb Antifouling Electrochemical Biosensor Based on Macrocycle Encapsulation Strategy for Biomarker Analysis in Complex BiofluidsACS Sensors · 2025
- Self-Powered Anti-Interference Photoelectrochemical Immunosensor Enabled by a Ferroelectric Hybrid Coupled with a Platinum-Doped Peptide HydrogelAnalytical Chemistry · 2026
- Electrodeposited Anisotropic Pt Nanoarrays for Broad-Range Electrochemical BiosensingJournal of Electrochemical Science and Technology · 2026
- A Robust Biosensor Based on the Pd−S Bond-Immobilized Peptide toward Antifouling Electrochemical Detection of an Alzheimer’s Disease Biomarker in SerumACS Sensors · 2026