Comparative Validation of Vanadium(III) Chloride Reduction and Standard Methods for Nitrate Quantification in Organic-Rich Tropical Waters.
Olga-Inés Vallejo-Vargas, Edwin Alzate-Rodriguez, Mariana Espinoza, Natalia Londoño, Leonardo Beltrán-Angarita
Grupo de Estudio del Recurso Hídrico, Escuela de Tecnología Química-Facultad de Tecnologías, Universidad Tecnológica de Pereira, Pereira 660003, Colombia. · Grupo de Investigación Infección e Inmunidad, Programa de Medicina, Facultad Ciencias de la Salud, Universidad Tecnológica de Pereira, Pereira 660003, Colombia.
Key points
From the paper's conclusion- This study compared three standard methods (APHA 4500-NO3− B, E, and J) with an optimized vanadium(III) chloride (VCl3) reduction method coupled with the Griess reaction.
Abstract
Natural organic matter (NOM) can interfere with the determination of nitrate (NO3-) in tropical waters. This study compared three standard methods (APHA 4500-NO3- B, E, and J) with an optimized vanadium(III) chloride (VCl3) reduction method coupled with the Griess reaction. The VCl3 reaction was optimized at 1.0 M HCl in the VCl3 reagent, 60 °C, and 45 min. At dissolved organic carbon (DOC) above 3.0 mg C/L, direct ultraviolet (UV) spectrophotometry (Method B) overestimated nitrate, and its 275 nm correction exceeded the 10% rejection criterion of the method. Spike recovery with enzymatic reduction (Method J) decreased to 54.1 ± 4.2% at 20.0 mg C/L DOC, whereas cadmium (Method E) and VCl3 reduction gave 98.5 ± 2.2% and 101.2 ± 1.8%, respectively. For the VCl3 method, the limit of quantification (LOQ) was 0.010 mg N-NO3-/L (relative standard deviation, RSD, 3.8%; recovery 98.2% at this level), repeatability was 1.0-2.2% RSD, and inter-analyst intermediate precision was 2.2-3.8% RSD (cadmium reduction: 4.5-6.2%). In 12 natural water samples, the VCl3 and cadmium results differed by less than 2%. The VCl3 method avoids packed columns and cadmium waste.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine Learning-Assisted Colorimetric Quantification of Nitrite in Plateau Lake Waters.Analytical chemistry · 2026
- Wide‐Range Automated Kjeldahl Determination of Ammonium in Vanadium Redox Flow Battery Electrolytes for Industrial Quality ControlChemistrySelect · 2026
- Selective Voltammetric Quantification of Nitrite on Lead Deposited In SituElectroanalysis · 2026
- Deep learning-based classification of nitrate and nitrite concentrations from water samples using colorimetric test strip imagesEnvironmental Monitoring and Assessment · 2026
- From Potentiometric Titration to Electrometric Conductivity: A Critical Review and Metrological Comparison of ASTM D6470 and ASTM D3230 toward Method Replacement in Salt in Crude Analysis.Critical reviews in analytical chemistry · 2026
- Versatile Manganese Porphyrin, Capable of Detecting Iodide Anions by Spectrophotometric and Electrochemical MethodsMolecules · 2026