Determination of Acrylamide in Foods by Liquid Chromatography-Tandem Mass Spectrometry with a Porous Graphitic Carbon Column.
Huijiao Chen, Lingang Chen, Weiping Xie
Department of Physical and Chemical Laboratory, Quanzhou Center for Disease Control and Prevention (Quanzhou Health Supervision Institute), Quanzhou 362000, China.
Key points
From the paper's conclusion- A high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method was established for the determination of acrylamide in foods using a porous graphitic carbon (PGC) column for separation.
Abstract
A high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was established for the determination of acrylamide in foods using a porous graphitic carbon (PGC) column for separation. Samples were spiked with an isotopically labeled internal standard, extracted with acetonitrile-water, purified using a mixed-mode cation-exchange (MCX) solid-phase extraction cartridge, and then separated on a PGC column. By employing a single-step pass-through MCX clean-up, the inherent anti-interference capacity of the PGC column in complex matrices was evaluated. Methanol and 0.1% formic acid in water served as the mobile phase, and detection was performed in positive electrospray ionization mode with multiple reaction monitoring (MRM). Method validation was conducted using meat products and coffee samples, and the method was further applied to eight sample categories (n = 68), including potato chips, biscuits, instant coffee, and local specialty foods from southern Fujian. Acrylamide exhibited good linearity over the concentration range of 10-500 µg/L, with correlation coefficients of 0.9994-0.9998. The limit of detection (LOD) was 0.81-1.38 µg/kg, and the limit of quantification (LOQ) was 2.70-4.61 µg/kg. The mean spiked recovery was 94.2-103.4%, with a relative standard deviation (RSD) of 0.8-5.4%, and the matrix effect was 60.6-76.5% for the PGC column, compared with 46.8-51.3% for the C18 column. A paired t-test showed that the PGC column exhibited a significantly higher matrix effect (ME) value (i.e., less signal suppression) than the C18 column (p < 0.05). Owing to the strong retention characteristics of the PGC column for polar compounds, the method effectively improves chromatographic separation and reduces co-eluting interferences. It provides a practical approach for reducing matrix interference and improving sensitivity in matrices where interferences are well-controlled (e.g., meat products), while effectively overcoming the overestimation of acrylamide in highly complex matrices like coffee, with a residual matrix effect corrected by the isotope-labeled internal standard specifically within these validated matrices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Processing-Dependent Acrylamide Formation in French Fries: Optimisation of QuEChERS-Based Extraction and HPLC-PDA Determination.Molecules (Basel, Switzerland) · 2026
- Simultaneous determination of acrylamide, Glycidamide, and Methylacrylamide in plant-based beverages using μ-dispersive solid phase extraction and HPLC-PDA: Development, validation, and occurrenceFood Chemistry · 2025
- Mechanism-guided mitigation of acrylamide in thermally processed foods: emerging technologies and analytical verification.Frontiers in nutrition · 2026
- Investigating the effect of different additives on the acrylamide formation process in bread tahdig: A health risk assessment studyApplied Food Research · 2026
- Analysis of acrylamide in food additives via Michael addition derivatization and liquid chromatography-tandem mass spectrometry.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2026
- Prediction of acrylamide levels in baked bread using a portable near-infrared spectroscopy sensorFood Control · 2026