A Robust AQbD-Based RP-HPLC Method for Simultaneous Quantification of Acyclovir and Doxepin Hydrochloride in Bulk and Topical Cream Formulation.
Akshay Kumar, Mohit Kumar, Abhishek Saini, Mohit Agrawal, Urvashi Khatri, Neeraj Choudhary, Dinesh Kumar, Ammar Cherif
Chitkara College of Pharmacy, Chitkara University, Rajpura 140401, India. · Ayush Herbs Pvt. Ltd., Kangra 176047, India.
Key points
From the paper's conclusion- In conclusion, the proposed AQbD-based RP-HPLC method is suitable for routine quantitative analysis and quality control of acyclovir and doxepin hydrochloride in combined topical formulations.
Abstract
The present study describes the development and validation of a simple, rapid, and reliable RP-HPLC method for the simultaneous estimation of acyclovir and doxepin hydrochloride in bulk and topical cream formulation using an Analytical Quality by Design (AQbD) approach. The combination of acyclovir, an antiviral agent, and doxepin, an antipruritic and anti-inflammatory drug, offers a combined topical approach for the management of herpes-associated skin conditions. The method development was guided by a predefined Analytical Target Profile (ATP), followed by systematic risk assessment to identify critical quality attributes (CQAs) and critical method parameters (CMPs). The central composite design (CCD) was employed to optimize key chromatographic variables, including mobile phase composition and flow rate. The chromatographic separation was achieved on a C18 column using an isocratic mobile phase of acetonitrile and water (40:60 v/v) at a flow rate of 1.0 mL/min, with UV detection at 240 nm. The retention times were found to be 2.58 min for acyclovir and 4.64 min for doxepin hydrochloride, indicating efficient separation with good peak symmetry. The method was validated according to ICH Q2(R2) guidelines and demonstrated excellent linearity over the concentration ranges of 2-10 µg/mL (acyclovir) and 12-28 µg/mL (doxepin hydrochloride), with correlation coefficients greater than 0.997. The method exhibited high precision (%RSD < 2%), accuracy (recovery within 99-101%), and good sensitivity with low LOD and LOQ values. The robustness studies confirmed the reliability of the method under small, deliberate variations in chromatographic conditions. The developed cream formulation showed uniform drug content and satisfactory in vitro drug release, with a sustained release profile reaching approximately 96% over 24 h. In conclusion, the proposed AQbD-based RP-HPLC method is suitable for routine quantitative analysis and quality control of acyclovir and doxepin hydrochloride in combined topical formulations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Central Composite Design Approach Stability-Indicating RP-HPLC Analysis for Simultaneous Estimation of Monoclonal Antibodies in Bulk and Combined Dosage Form.Assay and drug development technologies · 2026
- Quality by design based analytical (RP-HPLC) method development and validation of coenzyme q10 in single and combination with clomiphene citrate: An extensive reviewLetters in Drug Design & Discovery · 2025
- Strategic integration of AQbD principles in RP-HPLC: a business perspective on drug quantification.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- Analytical quality-by-design-guided green RP-HPLC method to quantify cyclosporin A and luteolin simultaneously in a combination of two drug solutions and two drug-loaded next-generation emulsions or nanocapsules.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- AQbD-Driven Green RP-HPLC Method Development and Validation for Simultaneous Quantification of Apremilast and Quercetin in Nanostructured Lipid Carriers.Drug development and industrial pharmacy · 2026
- Quality by design-driven RP-HPLC method for simultaneous determination of α-mangostin and cardamonin: validation, process capability, and multidimensional sustainability assessment.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026