Analytical Determination of Heavy Metals in Water Using Carbon-Based Materials
Zhazira Mukatayeva, D.B. Konarbay, Yrysgul Bakytkarim, Nurgul Shadin, Yerbol Tileuberdi
Abai Kazakh National Pedagogical University
Key points
From the paper's conclusion- Overall, this review not only summarizes current performance benchmarks of carbon-based sensors but also identifies key challenges, including long-term stability, selectivity under multi-ion interference, and large-scale device integration, while outlining future directions toward portable multisensor water-quality monitoring systems.
Abstract
This review presents a critical and comparative analysis of carbon-based electrochemical sensing platforms for the determination of heavy metal ions in water, with emphasis on Pb2+, Cd2+, and Hg2+. The growing discharge of industrial and mining effluents has led to persistent contamination of aquatic environments by toxic metals, creating an urgent need for sensitive, rapid, and field-deployable analytical technologies. Carbon-based nanomaterials, including graphene, carbon nanotubes (CNTs), and MXene, have emerged as key functional components in modern electrochemical sensors due to their high electrical conductivity, large surface area, and tunable surface chemistry. Based on reported studies, typical detection limits for Pb2+ and Cd2+ using differential pulse voltammetry (DPV) on glassy carbon and thin-film electrodes are in the range of 0.4–1.2 µg/L. For integrated thin-film sensing systems, limits of detection of 0.8–1.2 µg/L are commonly achieved. MXene-based platforms further enhance sensitivity and enable Hg2+ detection with linear response ranges typically between 1 and 5 µg/L, accompanied by clear electrochemical or optical signals. Beyond conventional electrochemical detection, this review specifically highlights self-sustaining visual sensors based on MXene integrated with enzyme-driven bioelectrochemical systems, such as glucose oxidase (GOD) and Prussian blue (PB) assembled on ITO substrates. These systems convert chemical energy into measurable colorimetric signals without external power sources, enabling direct visual identification of Hg2+ ions. Under optimized conditions (e.g., 5 mg/mL GOD and 5 mM glucose), stable and distinguishable color responses are achieved for rapid on-site monitoring. Overall, this review not only summarizes current performance benchmarks of carbon-based sensors but also identifies key challenges, including long-term stability, selectivity under multi-ion interference, and large-scale device integration, while outlining future directions toward portable multisensor water-quality monitoring systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Review on Tailored Carbon Dots for High‐Performance Heavy Metal Ion Sensing in Aquatic SystemsLuminescence · 2026
- Simultaneous Multi-Ion Heavy Metal Sensing Using Pulse and Stripping Voltammetry at Functionalized Nanomaterial-Modified Glassy Carbon ElectrodesInternational Journal of Molecular Sciences · 2026
- Integrating carbon dots to advance measuring aquatic metal ion pollutants: Sensing and computational modelingCarbon Resources Conversion · 2026
- MXene@SiC Nanocomposite-Modified Electrode for Sensitive Electrochemical Detection of Cadmium (II) IonsC · 2026
- Waste-to-sensor: high-sensitivity detection of heavy metals in water using Arc-ferrite/N-rGO nanocomposites from industrial and electronic wastenpj Clean Water · 2026
- Advanced carbon dot- and quantum dot-based sensors for lead ion detection: a comprehensive review.Nanoscale advances · 2026