Crowding Predicts Airborne Bacterial Load and Resistant Staphylococci Across Hospital Zones.
Mawahib A Ahmed, Layali M Alharbi, Basmah Alharbi, Mishaal A Alrsheed, Asmaa Elkady, Abla D M Al-Harbi, Khaled S Allemailem
Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University, Buraydah 51452, Saudi Arabia. · Department of Basic Health Sciences, College of Applied Medical Sciences, Qassim University, Buraydah 51452, Saudi Arabia.
Key points
From the paper's conclusion- We exposed 54 settle plates in six zones of a tertiary hospital in Qassim, Saudi Arabia, at three times of day over three rounds.
Abstract
Hospital air is monitored mainly in protected zones, yet crowded patient-facing services may carry more bacteria, including resistant staphylococci. We aimed to measure load, community composition and resistance together across clinical and service zones. We exposed 54 settle plates in six zones of a tertiary hospital in Qassim, Saudi Arabia, at three times of day over three rounds. Counts were analysed with negative-binomial models, community analysis, susceptibility testing and Monte Carlo exposure estimates. Bacterial load was 9.1 times higher in the phlebotomy unit than in the operating theatre (95% confidence interval 3.9-21.0) and 2.3 times higher at 12:00 than at 07:00 (1.2-4.2), and rose with occupancy. Every plate stayed within the maximum acceptable index for its risk class, but two operating-theatre plates exceeded the ultraclean limit. Human-associated staphylococci dominated, zone explained 42% of community variation and all six indoor staphylococcal species met multidrug-resistance (MDR) criteria and were reported methicillin-resistant at species level. A phlebotomy worker was estimated to inhale a median of 1765 colony-forming units per 8-h shift (95% uncertainty interval 497-6365), 968 (265-3598) from MDR species. Nationally, Staphylococcus aureus rose from fifth to second among pathogens behind lower-respiratory-infection deaths between 1990 and 2023. Crowded service areas deserve a place in hospital air surveillance alongside protected zones.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Airborne occurrence and genomic relatedness of multidrug-resistant Staphylococcus epidermidis in hospital wards: a prospective genomic epidemiology studyAntimicrobial Resistance & Infection Control · 2026
- Developing a sensitive indoor air surveillance approach for nosocomial pathogens and antimicrobial resistancebioRxiv · 2026
- Comprehensive analysis of air and surface hospital microbiomes uncovers potential hotspots and avenues for transmission of diverse pathogens linked to hospital-acquired infectionsbioRxiv · 2026
- Burden of healthcare-associated infections in tertiary care hospitals in six countries of the Gulf Cooperation Council: A point prevalence survey.Epidemiology and infection · 2026
- Within-species phenotypic resistance rather than community turnover tracks antimicrobial usage in Staphylococcus aureus on swine farms.Environmental pollution (Barking, Essex : 1987) · 2026
- Spatiotemporal Contamination Characteristics, Bacterial Community Structure, and Airflow-Mediated Transport of Bacterial Aerosols in a Pediatric Emergency Consulting Room.Environmental research · 2026