Micromachines

Fixed-Bias Stream Computing in Filamentary RRAM Crossbars: A Measurement-Calibrated Device-Circuit Study.

Melika Morsali, Pranav Choori, Ethan C Ahn, Mircea R Stan

Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA 22904, USA. · Department of Electrical and Computer Engineering, George Mason University, Fairfax, VA 22030, USA.

Key points

From the paper's conclusion
  • We present a measurement-calibrated device-to-circuit study of this error and show how it can be mitigated by replacing voltage-amplitude inputs with fixed-bias time-domain inputs, as in Asynchronous Stream Computing (ASC), which uses constant-amplitude sigma–delta streams.

Abstract

Filamentary metal-oxide RRAM conducts through a tunneling gap for which the current grows exponentially with bias, so its Read-range I-V characteristic follows a sinh(V/V0) law. This introduces a systematic, input-dependent multiply-accumulate (MAC) error when used in analog Compute-in-Memory (CiM) accelerators with inputs encoded as voltage amplitudes. Because the nonlinearity also varies with resistance state, a single correction factor cannot generally compensate for all programmed weights. We present a measurement-calibrated device-to-circuit study of this error and show how it can be mitigated by replacing voltage-amplitude inputs with fixed-bias time-domain inputs, as in Asynchronous Stream Computing (ASC), which uses constant-amplitude sigma-delta streams. RRAM samples from two independent processes, Pt/Ti/HfO2/Ta/Pt and Al/TiO2/Au/Ti, are characterized, and the Stanford compact model is calibrated to each process. Together with two published parameter sets, the fitted nonlinearity coefficient V0 spans 0.29-0.55 V across four stacks and varies with resistance state within individual devices. In 65 nm circuit simulations, voltage-amplitude encoding incurs up to 30% relative error in a single cell and approximately 8.5% full-scale-normalized error in single-bitline crossbars of 4 to 256 rows. At a 5 ms accumulation window, ASC reduces the array error to 0.4-0.8% with ideal-integrator readout and 0.8-2.3% with transistor-level AΣΔM readout. Under measured device variability, group-balanced Monte Carlo simulations yield 7.6-9.2% analog error versus 0.5-0.7% ASC error. Wire resistance reduces the fixed-bias advantage but does not eliminate it within the simulated conditions. First-order energy estimates identify accumulation time and cell read current as important costs, while practical implementation also requires wordline drivers and high-ratio current division.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Fixed-Bias Stream Computing in Filamentary RRAM Crossbars: A Measurement-Calibrated Device-Circuit Study — Science Skim