An Ultraminiature Pressure Sensor Integrated into Acupuncture Needle Tip for In Vivo Monitoring of Local Muscle Response.
Ci Song, Zheng Yu, Xiaohong Chen, Xiaojing Liu, Wei Li, Zao Ni, Shuguang Yu, Xinxin Li
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China. · School of Intelligent Medicine, Chengdu University of Traditional Chinese Medicine, Chengdu 611137, China.
Key points
From the paper's conclusion- These results demonstrate the feasibility of monitoring local muscle response during acupuncture and their potential to provide quantitative feedback for needle manipulation.
Abstract
Real-time monitoring of local muscle response during acupuncture could reveal mechanisms underlying acupuncture and provide objective feedback to support more precise needle control. However, the small dimensions of acupuncture needles impose stringent constraints on sensor miniaturization and packaging. This study presents an ultraminiature pressure sensor integrated into the tip of a 450-μm-diameter acupuncture needle. The sensor measures 200 × 1250 × 50 μm3 and incorporates an elongated pressure-sensitive diaphragm. Wafer-level AuSn solder deposition and thermocompression soldering connect the chip to an ultrafine wire ribbon routed through the 230-μm-diameter needle lumen. A 1.3-μm-thick Parylene C coating provides electrical insulation. After coating, the sensor exhibited a sensitivity of 40.3 μV/kPa at a 3.3 V excitation, retaining 78.4% of its uncoated sensitivity. Characterization over 90-150 kPa absolute and 25-45 °C yielded a maximum nonlinearity of approximately 0.73% of full scale (FS). The coated sensor exhibited a maximum hysteresis of 2.52% FS. In vivo experiments at the Zusanli acupoint in rats recorded pressure variations during thrusting-lifting manipulation. These results demonstrate the feasibility of monitoring local muscle response during acupuncture and their potential to provide quantitative feedback for needle manipulation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acupuncture Needle-Based Biosensors: Interface Engineering, Sensing Strategies, and Applications.Biosensors · 2026
- High Sensitivity Iontronic Flexible Pressure Sensor Based on Microstructured Electrodes for Wearable DevicesIEEE Instrumentation & Measurement Magazine · 2026
- Ultrasensitive and Wide‐Range Ionic Pressure Sensors Toward Intelligent Assessment of Traditional Chinese Medicine Pulse and Oral Occlusal HealthAdvanced Functional Materials · 2026
- Multiplexed catheter-integrated pressure sensing system for endoluminal interventions.Microsystems & nanoengineering · 2026
- Shape‐Adaptive Mechanical Sensing Patches With Laser‐Microtextured Conductive Topology for Biointerfaced ElectronicsAdvanced Functional Materials · 2026
- Validation of a Signal Processing and Sensor Data Fusion Pipeline for Cochlear Implant Insertion Force MeasurementCurrent Directions in Biomedical Engineering · 2026