Development of Renal Denervation Catheter Based on Piezoelectric Ultrasonic Transducer.
Qian Li, Tao Zhou, Dan Qin, Yongliang Wu, Xiang Li, Song Li, Xiong Chen, Zhipeng Wu
Acoustic Life Science Co., Ltd., Shanghai 201203, China. · Sonoscape Medical (Wuhan) Co., Ltd., Wuhan 430074, China.
Key points
From the paper's conclusion- Owing to the use of a piezoelectric ceramic tube as the ultrasonic transducer, the RDN catheter is designed to provide 360° circumferential acoustic exposure around the renal artery.
Abstract
In this manuscript, a miniaturized ultrasonic Renal Denervation (RDN) catheter for removing sympathetic nerves around the renal artery is proposed. The RDN catheter consists of an ultrasonic transducer, a balloon catheter and a control system. Owing to the use of a piezoelectric ceramic tube as the ultrasonic transducer, the RDN catheter is designed to provide 360° circumferential acoustic exposure around the renal artery. The piezoelectric ceramic tube has an active length of 6 mm, an inner diameter of 1.1 mm, and an outer diameter of 1.6 mm and the material of piezoelectric ceramic tube is PZT8. The balloon catheter of the proposed RDN catheter is designed and optimized so that the diameter of the portion inserted into the vessel is ≤1.8 mm, with the aim of enabling access to the renal artery via Transradial Access (TRA). In addition, a liquid circulation system is integrated into the balloon catheter to cool the ultrasonic transducer, with the aim of limiting heating near the renal artery wall. The measured resonant and anti-resonant frequencies of the ultrasonic transducer are 8.72 MHz and 9.69 MHz, respectively. Under 70 W input electrical excitation at 9.69 MHz, the average acoustic pressure measured at 6-7 mm from the catheter surface is 2.11 MPa. In addition, the control system prototype is also developed. Finally, the thermal feasibility of the proposed catheter is evaluated through phantoms and ex vivo tissues. In the phantom, visible whitening appears by 0.5 s, and an annular whitened region is evident by 8 s; at 15 s, its image-estimated thickness is approximately 3.6 mm, with an adjacent transparent interval of approximately 1.2 mm. Ex vivo porcine liver also shows macroscopic discoloration consistent with thermal denaturation. These observations support the preliminary acoustic and thermal feasibility of the proposed RDN catheter.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Dual-mode Ultrasound Transducer Based on Textured Ceramic for Image-guided Interstitial Ablationn.IEEE transactions on ultrasonics · 2026
- LN-PMUT ultrasonic transducer enables instantaneous blood pressure reduction via renal hilar implantation.Biomaterials · 2026
- Ultrasound renal denervation for treatment-resistant hypertension with severe left ventricular hypertrophy.Hypertension research : official journal of the Japanese Society of Hypertension · 2026
- Miniaturized piezoelectric tube actuated catheter (μPTAC) enabling distal actuation for intravascular optical coherence tomography.Ultrasonics · 2026
- A Cymbal Transducer as a Single-Element Device for Enhanced Cavitation Generation.IEEE transactions on ultrasonics · 2026
- Renal Denervation in Modern Hypertension Care: From Early Promise to Evidence-Based Clinical Integration.Advances in kidney disease and health · 2026