Fault Mechanism Analysis of MEMS Gyroscopes Under High-Overload Environment.
Bin Yan, Zhongyang Guo, Yilong Chen, Jiantao Zhao, Yujun Yang, Shugang Zhang, Boyu Hao, Huiliang Cao
Xi'an Microelectronics Technology Institute, Xi'an 710018, China. · Anhui XDLK Microsystem Corporation Limited, Bengbu 233300, China.
Key points
From the paper's conclusion- The results are interpreted as a mechanism-oriented case study, with residual stress redistribution and boundary condition changes considered possible explanations requiring further physical verification.
Abstract
High-overload micro-electro-mechanical system (MEMS) gyroscopes can retain an output after impact while exhibiting degraded sensing performance. This study examines a packaged four-mass gyroscope using a coupled mechanical model, transient finite element analysis and a single-device high-overload test. The transient model yields a peak stress of 181.412 MPa in the sensitive structure. The reported drive and sense frequencies change from 7734.0 and 7755.7 Hz to 7745.2 and 7751.3 Hz, respectively, reducing the frequency split from 21.7 to 6.1 Hz. Under a calibrated impact of 16,190 g, the zero-rate output changes from 0.00178 to 0.06733°/s and the reported bias instability from 3.52 to 143.8°/h. A smaller frequency split therefore does not establish improved post-impact performance. For unchanged effective modal mass, the reported frequencies imply equivalent stiffness changes of approximately +0.290% and -0.113%. These estimates do not establish silicon plasticity or uniquely identify a package mechanism. The results are interpreted as a mechanism-oriented case study, with residual stress redistribution and boundary condition changes considered possible explanations requiring further physical verification. Population reliability and repeatability are outside the evidence provided by this single-device, single-event dataset.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability Assessment of MEMS Gyroscopes via Dual-Mechanism Synergistic Degradation: A Generalized Linear Model with Physics-Informed Wiener ProcessesSensors · 2026
- Stability of Operating Noise for Packaged MEMS Gyroscopes in Low-Speed Vehicle Motion Scenarios.Micromachines · 2026
- Shock-resistant design of a quartz tuning fork gyroscopeJournal of Physics: Conference Series · 2026
- Effect of High Temperature During Packaging Process on the Dynamic Parameter Stability of Hemispherical Resonator Gyroscope.Micromachines · 2026
- Design, Implementation and Calibration of Analog Gyro-Based Angular Rate Data Acquisition System for High-Spinning Rotation Rate Applications.Sensors (Basel, Switzerland) · 2026
- Frequency Stability Degradation in Quartz and MEMS Oscillators.Sensors (Basel, Switzerland) · 2026