Design of a Textile-Integrated Piezoelectric Braided Cord Sensor for Sleep Apnea Monitoring.
Yoshiro Tajitsu, Osamu Takeuchi, Saki Shimada, Takuto Nonomura
Center for Innovation & Creativity, Kansai University, Osaka 564-8680, Japan. · Faculty of Foreign Language Studies, Kansai University, Osaka 564-8680, Japan.
Key points
From the paper's conclusion- These findings demonstrate the potential of the proposed sensing approach and provide a basis for future clinical investigations.
Abstract
Piezoelectric braided cords composed of poly-L-lactic acid (PLLA) fibers can be integrated into textiles to detect mechanical signals without requiring sensors to be attached directly to the body. In this study, we investigated the potential of a bed-sheet-integrated piezoelectric braided cord sensor for unobtrusive physiological monitoring during sleep, using sleep apnea as an example of its possible applications. Finite element method (FEM) analysis was performed to qualitatively examine the directional characteristics of the piezoelectric response. Guided by these qualitative findings, a bed-sheet sensor with a multi-orientation stitching configuration was developed through iterative prototyping and experimental evaluation. Piezoelectric braided cord signals were recorded from 23 participants during their routine clinical polysomnography (PSG) examinations. The developed sensor enabled the detection of respiration- and pulse-related mechanical signals during sleep. During the initial analysis of data from a small number of these participants, we observed that a pulse-related periodic component remained detectable in the respiratory signal when respiratory motion decreased during apnea. Based on this observation, an apnea-related signal detection algorithm was developed and subsequently applied to the complete dataset of 23 participants. The sensor-based analysis was performed independently of the physicians' PSG-based assessments. For the 18 participants with available physician-based apnea event assessments, the sensor-detected event counts were compared with PSG-based counts within 5-min intervals, without event-by-event temporal matching. These findings demonstrate the potential of the proposed sensing approach and provide a basis for future clinical investigations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-Strength and Weavable Smart Nanoyarn Fabric for Unconstrained Ballistocardiogram Monitoring in Home SettingsACS Applied Electronic Materials · 2026
- Flexible Piezoresistive Yarn Pressure Sensor for Arterial Blood Pressure Waveform Measurement.Biosensors · 2026
- Flexible Piezoelectric Sensor for Real-Time Comprehensive Cardiovascular MonitoringACS Applied Electronic Materials · 2026
- Wearable Sensors for Monitoring Abnormalities in Sleep-Related BreathingACS Applied Materials & Interfaces · 2026
- Humidity-Strain Synergized Adaptive NO Sensing in a Pd-Carbon Nanocoil Fabric for Respiratory-State Recognition.ACS applied materials & interfaces · 2026
- Bioelectronic Wearable Sensors Produced by Computerized Embroidery Using a Dual Thread Approach.Small (Weinheim an der Bergstrasse, Germany) · 2026