Electrochemical Stability of Electrodeposited PEDOT:PSS Neural Stimulation Electrodes.
Amirhossein Azami, Yupeng Wu, Christopher K Nguyen, Justin R Abbott, Mark E Orazem, Kevin J Otto, Stuart F Cogan, Brian N Kim
Department of Electrical Engineering and Computer Science, University of Texas at Dallas, Richardson, TX 75080, USA. · Department of Material Science and Engineering, University of Texas at Dallas, Richardson, TX 75080, USA.
Key points
From the paper's conclusion- These results identified –0.6 V as an electrochemical limit for PEDOT:PSS stability on gold and implicate the reduction and de-doping of PEDOT:PSS, and sequalae, in the observed PEDOT:PSS degradation.
Abstract
Microelectrode arrays are used for neural stimulation and recording; however, their performance is limited by the high impedance and low charge-injection capacity of conventional metallic interfaces. To overcome these challenges, a variety of coatings, including metal oxides, carbon nanotubes, and conductive polymers, are applied to improve the electrochemical performance of microelectrode arrays. Among these materials, poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) has gained significant attention due to its low impedance, high charge-injection capacity, and compatibility with microfabrication processes. Despite these advantages, the long-term electrochemical stability of PEDOT:PSS at high levels of stimulation charge injection remains insufficiently understood. In this study, we investigated the stability of PEDOT:PSS films electrodeposited on gold microelectrodes for prolonged electrical stimulation. Voltage transient (VT) analysis revealed that PEDOT:PSS degradation occurs when the maximum cathodic excursion (Emc) exceeds -0.6 V versus Ag|AgCl. The degradation is accompanied by the appearance of asymmetric access voltages and a voltage inversion in the anodal phase of the VT. Electrochemical impedance spectroscopy (EIS) revealed a sharp increase in PEDOT:PSS impedance at negative DC bias potentials, beginning at -0.5 V and increasing as the potential became more negative. These results identified -0.6 V as an electrochemical limit for PEDOT:PSS stability on gold and implicate the reduction and de-doping of PEDOT:PSS, and sequalae, in the observed PEDOT:PSS degradation. Nonetheless, PEDOT:PSS electrodes had stable charge-injection capacities of 3.6 mC/cm2 (200 µs pulse width) over the course of 200 million pulses.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrochemical Deformation of PEDOT:PSS Drives Mechanosensitive Cell ActivationbioRxiv · 2026
- PEDOT:PSS—A Key Material for BioelectronicsAdvanced Science · 2025
- PEDOT:PSS in peripheral nerve injury repair: electrical stimulation, neural interfaces, and neural regenerative mechanismsMaterials Today Bio · 2025
- Polydopamine-doped PEDOT interfaces improve cell-electrode interactions and neural signal transmissionScientific Reports · 2026
- Nanopatterned Black Silicon Electrodes for High-Charge-Density Intraspinal Microstimulation.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
- Systematic Errors in DC Offset Measurement and Mitigation at Neurostimulation Electrodes: Causes, Implications and SolutionsbioRxiv · 2026