Direct Molding of Luer Connections in PDMS Microfluidic Devices: Comparison with Conventional Interface Methods.
Gina Layedra, Alexander Paolo Vallejo Janeta, Rocio Gimenez, Ramiro Isa Jara, Ana Belén Peñaherrera-Pazmiño, Arianna Mayorga-Ramos, Gustavo Rosero, Maximiliano S Perez,
Special Coatings and Nanostructures Engineering (IREN), National Technological University, Buenos Aires 1706, Argentina. · Laboratorio de IA "A.M. Turing", Facultad de Informática y Electrónica, Escuela Politécnica de Chimborazo (ESPOCH), Riobamba EC060155, Ecuador.
Key points
From the paper's conclusion- Overall, this molding strategy provides a robust and reusable Luer-compatible interface for integrating standardized connections into soft-lithography-based microfluidic platforms.
Abstract
Reliable world-to-chip connections remain a critical challenge in PDMS-based microfluidic devices, particularly under high-pressure flow conditions. In this work, we present a simple, low-cost, and reproducible method to directly mold male Luer cone fittings into PDMS devices during fabrication, without compromising the geometry of microchannels. To evaluate the effectiveness of this approach, we compared the performance of three connection types-PTFE tubing, metal pipes, and molded Luer adaptors-by measuring the infusion pressure at which fluid leakage occurred. Devices with integrated Luer adaptors consistently withstood higher pressures (up to 1555 mbar) with reduced variability across repeated connection cycles, while PTFE and metal connections failed at lower pressures and showed inconsistent leakage behavior. As a biological proof of concept, Staphylococcus aureus biofilms were grown in the microfluidic channels under continuous perfusion and subsequently exposed to flow rates of 50, 83.3, and 116.7 µL/min. Image analysis showed an initial biofilm-covered area of 14.22% of the analyzed channel area, while the biofilm areas remaining after exposure to 50, 83.3, and 116.7 µL/min were 1.39, 0.85, and 0.32%, respectively. The final measurement represented a reduction of approximately 97.7% relative to the initial biofilm coverage. The molded Luer connections maintained stable fluid delivery during biofilm cultivation and flow-induced detachment, supporting their use in biological microfluidic applications. Overall, this molding strategy provides a robust and reusable Luer-compatible interface for integrating standardized connections into soft-lithography-based microfluidic platforms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bonding with a Benchtop UV Ozone Cleaner: A Practical Guide to Prepare a Microfluidic Chip.Micromachines · 2026
- Agile manufacturing of PDMS microfluidic devices for cell culture without a clean roombioRxiv · 2026
- Construction Methods for Hybrid Polycarbonate-Silicon Microfluidic Devices.Journal of visualized experiments : JoVE · 2026
- Microfluidic Devices for Imaging and Biochemistry Analysis of Microbes Under Mechanical PressurebioRxiv · 2026
- Stop-Flow Lithography Using Hydrodynamic Flow Resistance Regulation and Hydraulic Compliance Minimization for Size-Tunable Anisotropic Multilayered Microparticles FabricationbioRxiv · 2026
- Redox-active Polydopamine-copper network on hydrophilic silicone polymers for coupled antifouling and antimicrobial interfaces.Journal of colloid and interface science · 2026