MicromachinesOpen accessCompliant mechanism

Magnetic Milligripper Platform for Biomedical and Biological Applications.

Doha Abdelrahman, Alain Savary, Bernard Feuillard, Marc Heuschkel, Dario Principi, Adrien Roux, Christophe Besson

School of Business and Engineering Vaud (HEIG-VD), University of Applied Science of Western Switzerland (HES-SO), 1401 Yverdon-les-Bains, Switzerland. · School of Engineering, Architecture and Landscape of Geneva (HEPIA), University of Applied Sciences and Arts Western Switzerland (HES-SO), 1202 Geneva, Switzerland.

Key points

From the paper's conclusion
  • The strong agreement between analytical, numerical, and experimental results establishes this architecture as a mechanically robust and scalable proof-of-concept platform for magnetic micromanipulation, with direct relevance to future minimally invasive biomedical applications.

Abstract

Achieving precise, untethered manipulation at the millimeter scale remains a fundamental challenge in minimally invasive medicine. Magnetic milligrippers have emerged as promising untethered tools for grasping, transporting, and releasing objects in confined anatomical environments, yet most existing rigid designs rely on multi-component assemblies with dedicated hinges or joints that require complex fabrication processes. Here, we present a simple, cost-effective rigid magnetic milligripper based on a folded titanium structure with two inclined permanent magnets. Actuated by a three-axis Helmholtz-Maxwell coil system, it enables orientation and translation control, as well as reversible opening. The actuation platform is coupled to a joystick-based control interface, allowing intuitive, real-time steering and opening of the milligripper by a single operator. The design is established with an analytical magnetic dipole model and validated through both finite-element simulations and experimental characterization, which together confirm reproducible, fully elastic operation across the investigated actuation range. The strong agreement between analytical, numerical, and experimental results establishes this architecture as a mechanically robust and scalable proof-of-concept platform for magnetic micromanipulation, with direct relevance to future minimally invasive biomedical applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Magnetic Milligripper Platform for Biomedical and Biological Applications — Science Skim