Micromachines

Electrode-Geometry Control of Normal Electric-Field Distributions and Electrostatic Loading on Sessile-Droplet Interfaces: A Finite-Difference Study with a Finite-Element Cross-Check and Surrogate-Assisted Design Exploration.

Fahad Sulaiman Obaid, Muhammed Anaz Khan

Department of Mechanical Engineering, College of Engineering, University of Bisha, P.O. Box 551, Bisha 61922, Saudi Arabia.

Key points

From the paper's conclusion
  • The results establish electrode geometry as a controllable electrostatic-loading parameter while explicitly deferring coupled stability analysis and experimental validation.

Abstract

Electrohydrodynamic emission from a sessile droplet depends on a coupled balance among electric traction, capillarity, gravity, charge transport and liquid motion. The present work addresses only the electrostatic-loading part of that problem. Verification-backed axisymmetric and three-dimensional Laplace solvers are used to map how parallel-plate, on-axis-pin, off-axis-pin and bipolar double-pin electrodes redistribute the normal electric field over a prescribed conducting water-droplet interface. The primary response is the dimensionless electric capillary number, CaE = ε0En2Rv/γ. To compare geometries on a common voltage scale, V1 is defined as the applied voltage at which the peak prescribed-interface loading reaches CaE = 1. V1 is a normalisation voltage and not a jetting or stability threshold. The axisymmetric solver reproduces the exact conducting-hemisphere solution to within 0.07% at the finest grid. The three-dimensional finite-difference results are mesh-assessed, and their normalised surface-field topology is cross-checked against an independently implemented Galerkin finite-element model. At 4 kV, the finite parallel-plate cell produces an apex enhancement of 3.24 relative to V/H. Replacing the plate with an on-axis 1 mm pin reduces the apex field by 39.5%, which corresponds to a 63% reduction in CaE, and increases V1 from approximately 5.0 to 8.2 kV. Lateral pin displacement moves the surface-field maximum away from the apex and produces a broad nominal plateau near d = 5-7 mm, although the sub-grid steering distance remains sensitive to mesh and extraction settings. The bipolar double-pin configuration produces two symmetric surface-field maxima together with a near-null at the apex. This topology, but not its absolute magnitude, is reproduced by the finite-element cross-check. A Gaussian-process model interpolates the one-dimensional offset family accurately under leave-one-offset-out validation (R2 = 0.999). Four Bayesian-optimisation trials locate the broad steering plateau but show no visible evaluation-count advantage over random sampling in this one-dimensional test. A three-mesh study gives a reported field-magnitude mesh-sensitivity estimate of approximately 6.2% at the finest grid (rising to about 9.5% at the h = 0.20 mm production mesh) for the representative three-dimensional case, and an indicative combined-uncertainty band of approximately 10% is shown for V1 in the exploratory trade-off plot. Illustrative Young-Laplace profiles at contact angles of 70° to 110° preserve the comparative pin-versus-plate field reduction, whereas V1 varies by up to approximately 50%. A simplified Peek-law screening estimate places corona inception (the pin being cathodic) in the approximate range of 4.8-10 kV, which is comparable to the on-axis-pin V1, so gas discharge may intervene before large electrocapillary loading is reached in ambient air. The results establish electrode geometry as a controllable electrostatic-loading parameter while explicitly deferring coupled stability analysis and experimental validation. By resolving this loading on a single exact-solution-verified basis, the study quantifies electrode geometry as a control parameter that idealised enhancement factors and the nominal gap field cannot capture and provides a verified fixed-interface reference state for subsequent coupled electrohydrodynamic modelling.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Electrode-Geometry Control of Normal Electric-Field Distributions and Electrostatic Loading on Sessile-Droplet Interfaces: A Finite-Difference Study with a Finite-Element Cross-Check and Surrogate-Assisted Design Exploration — Science Skim