A Statistical Framework for Nonlinear Calibration of a Single FBG Sensor Under Coupled Pressure–Temperature Loading
Reza Diharja, Sasono Rahardjo, Retno Wigajatri Purnamaningsih
Key points
From the paper's conclusion- This framework is practical and statistically sound for single FBG sensor calibration.
Abstract
Fiber Bragg Grating (FBG) sensors are widely used to measure pressure and temperature. However, when both are subjected to a coupled environment, the Bragg wavelengths influence each other, causing biased measurements if not properly calibrated. Most calibration models assume linear sensitivity, which may not hold across the entire operating range. This study proposes a five-step statistical calibration framework for a single FBG sensor under coupled pressure–temperature conditions: data preparation; fitting linear, quadratic, and cubic models; model selection using AIC/BIC; local sensitivity calculation; and contribution decomposition via Response Surface Methodology (RSM). The framework was tested on experimental data from an FBG sensor mounted on a metal membrane, at pressures of 0 MPa–2.0 MPa and temperatures of 5 °C–45 °C. Nonlinear models outperformed linear ones, with R¯2 values of 0.9725–0.9992. The model was validated using Leave-One-Out Cross-Validation (LOOCV), yielding an out-of-sample RMSE (Root Mean Square Error) of 0.0452 nm. Pressure sensitivity remained constant at 0.2250 nm/MPa, while temperature sensitivity decreased from 0.0224 nm/°C at 5 °C to 0.0069 nm/°C at 45 °C. RSM showed that pressure influences the slope and temperature influences the offset, with no significant interaction. Residual analysis satisfied the regression assumptions, and the combined uncertainty (0.008 nm/MPa; 0.0003 nm/°C) was much smaller than the observed sensitivity range, confirming that the variations are physical, not instrument noise. This framework is practical and statistically sound for single FBG sensor calibration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Calibration Identifiability and Conditional Design Choices for a Dual-FBG Displacement SensorJournal of Sensor and Actuator Networks · 2026
- Graded-Compliance Metal-Packaged FBG Strain Sensor for Cryogenic Strain Measurement of Reusable Launch VehiclesAerospace · 2026
- Compact FBG strain sensor for an accurate measurement method with wide-range temperature compensationOptics Express · 2025
- Design and Numerical Analysis of a Hybrid FBG-DBR Optical Platform for Multi-Sensor ApplicationsEPJ Web of Conferences · 2026
- A Brace-Integrated Fiber Bragg Grating Sensor with a Multi-Hardness Silicone Strain Transfer Substrate for Knee Flexion Monitoring: A Proof-of-Concept Study.Sensors (Basel, Switzerland) · 2026
- Thermal-strain-based calibration for high-accuracy shape reconstruction of fiber Bragg grating sensors.Optics express · 2026