Circulating Metabolites Associated with Corneal Biomechanics in Young Adults.
Jia-Yan Kai, Gang Liang, Shi-Yi Gong, Dan-Lin Li, Yue-Zu Li, Ya-Jie Zheng, Yu Qin, Chen-Wei Pan
School of Public Health, Suzhou Medical College of Soochow University, Suzhou 215123, China. · Department of Ophthalmology, The Affiliated Hospital of Yunnan University, Kunming 650021, China.
Key points
From the paper's conclusion- This study aimed to investigate associations between circulating metabolites and corneal biomechanics in young adults.
Abstract
Background: Corneal biomechanical properties are important determinants of ocular structural integrity, but their underlying metabolic determinants remain poorly understood. This study aimed to investigate associations between circulating metabolites and corneal biomechanics in young adults. Methods: We included 1628 participants from the Dali University Students Eye Health Study who underwent Corvis ST examination and serum metabolomic profiling. Associations between 415 metabolites and nine corneal biomechanical parameters were evaluated, including stiffness-related (SP-A1, IIR, and CBI), viscoelasticity-related (ARTh, DA Ratio, and HCT), and deformation-related parameters (DA, PD, and HC deflection). A multistep analytical strategy was used, comprising Spearman correlation screening, partial least squares regression, and multivariable linear regression without multiple-testing correction. Exploratory pathway enrichment analysis was performed using a threshold of false discovery rate (FDR)-adjusted p value < 0.10. Results: Twenty-two metabolites were associated with at least one corneal biomechanical parameter, with several showing associations across multiple biomechanical traits. Isocitric acid was positively associated with SP-A1 (β = 0.77, 95% CI: 0.05-1.49) but inversely associated with CBI (β = -0.01, 95% CI: -0.02 to -0.003), whereas o-methoxyphenylsulfate was inversely associated with Ambrosio relational thickness horizontal (β = -10.73, 95% CI: -17.99 to -3.48). Glycerophosphocholine and several other metabolites were positively associated with deformation-related parameters. Pathway enrichment analysis identified two significant pathways for SP-A1: the citrate cycle and glyoxylate and dicarboxylate metabolism. Conclusions: Our findings provide preliminary evidence that circulating metabolic profiles may be related to corneal biomechanical phenotypes and generate hypotheses for further investigation in independent populations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Associations between corneal biomechanical parameters and retinal superficial vessel density in young adults with varying myopia severity: a cross-sectional study.Frontiers in medicine · 2026
- Corvis ST Assessment of Corneal Biomechanical Properties in Patients with Type 2 Diabetes Mellitus.Medicina (Kaunas, Lithuania) · 2026
- Corneal Biomechanical Metrics by Corvis ST in a Mexican Population: Normative Data and Population-Specific Implications for Intraocular Pressure Assessment.Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026
- Role of Corneal Biomechanics in the Pathogenesis, Diagnosis, and Management of Glaucoma.Journal of ophthalmology · 2026
- Regional Dependence of Corvis ST Biomechanical Parameters on Corneal Material Properties: A Finite Element Study.Bioengineering (Basel, Switzerland) · 2026
- Corneal biomechanical properties and intraocular pressure assessment in pediatric type 1 diabetes mellitus: A comparative Corvis ST study.European journal of ophthalmology · 2026