Key points
From the paper's conclusion- The available evidence does not establish a single cutoff applicable to all patients with renal dysfunction.
Abstract
Background and Objectives: Initial high-sensitivity cardiac troponin I (hs-cTnI) measurements can be difficult to interpret in patients with renal dysfunction because elevated concentrations may occur without acute myocardial infarction (AMI). This systematic review compared reported optimal hs-cTnI cutoffs and their diagnostic performance across assay platforms and patient subgroups. Materials and Methods: PubMed/MEDLINE, Embase, the Cochrane Library, and Web of Science were searched from inception to 21 August 2026. Studies evaluating initial hs-cTnI measurements in adults with renal dysfunction and reporting diagnostic cutoffs with corresponding sensitivity and specificity for AMI were eligible. Risk of bias was assessed using QUADAS-2. Findings were synthesized narratively because of clinical and methodological heterogeneity; no meta-analysis was performed. Results: Five studies were included. In studies analyzing patients with an estimated glomerular filtration rate below 60 mL/min/1.73 m2 as a single group, optimal cutoffs ranged from 25.9 to 54 ng/L, with sensitivities of 76-88.4% and specificities of 83-90%. One study reported substantially higher cutoffs of 500-2610 ng/L across selected subgroups defined by CKD stage, age, and sex, with sensitivities of 80.4-91.4% and specificities of 92.1-100%. In patients receiving dialysis, cutoffs were 75 ng/L for hemodialysis and 144 ng/L for peritoneal dialysis, yielding sensitivities of 93.3% and 100% and specificities of 60.8% and 83.1%, respectively. All five studies were rated as having a high risk of bias in the index test domain. Conclusions: Reported initial hs-cTnI cutoffs varied considerably across assays and patient populations. The available evidence does not establish a single cutoff applicable to all patients with renal dysfunction. These thresholds require external validation and should be interpreted alongside clinical findings and serial troponin measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improving the diagnostic performance of troponin assays for acute myocardial infarction in renal impairmentHeart · 2026
- A-026 Impact of Chronic Kidney Disease on the Diagnostic Performance of the 0/1-Hour High-Sensitivity Cardiac Troponin T Triage AlgorithmClinical Chemistry · 2026
- The Intradialytic Changes in Cardiac Troponin I-A Systematic Review.Seminars in dialysis · 2026
- Rapid myocardial infarction rule-out: A single high-sensitivity cardiac troponin I and T threshold strategy for the Chinese emergency department.Clinica chimica acta; international journal of clinical chemistry · 2026
- Long forms of cardiac troponin T are independent of kidney function and improve the diagnosis of myocardial infarction.Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2026
- Clinical correlates, threshold sensitivity, and parsimonious modeling of high-sensitivity cardiac troponin I in health examination cohorts: a retrospective cross-sectional study with same-center temporal validation.Frontiers in medicine · 2026