Longitudinal Changes in Anxiety and Depression Following First Implantable Cardioverter-Defibrillator Implantation: A Prospective Observational Study.
Vincenzo Sgaramella, Antonio Gianluca Robles, Domenico Rosario Riccardo Chieppa, Domenico Gianfrancesco, Pierpaolo Vitti, Francesco Musaico, Francesca Pomarico, Paolo Pollice,
Department of Cardiology, Ospedale "L. Bonomo", 76123 Andria, Italy. · Department of Medicine and Health Sciences "V. Tiberio", University of Molise, 86100 Campobasso, Italy.
Key points
From the paper's conclusion- Results: Significant longitudinal changes were observed for both anxiety (Friedman Q = 63.32, p < 0.001; Kendall’s W = 0.34) and depression (Q = 68.36, p < 0.001; W = 0.37).
Abstract
Background and Objectives: ICD implantation is associated with psychological distress, but longitudinal patterns of anxiety and depression remain incompletely characterized. To evaluate the prevalence and longitudinal evolution of anxiety and depressive symptoms in patients undergoing first-time ICD implantation. Materials and Methods: This prospective study included 96 patients undergoing first ICD implantation. Anxiety and depression were assessed using the Hospital Anxiety and Depression Scale (HADS) at implantation (T0), one week post-discharge (T1), and six months later (T2). Data distribution was assessed using the Shapiro-Wilk test. Changes over time were analyzed using the Friedman test, Wilcoxon signed-rank tests, and Linear Mixed-Effects Models (LMM), with effect size (Kendall's W) and Spearman correlations. A sensitivity analysis evaluated severe distress thresholds (HADS ≥ 11). Results: Significant longitudinal changes were observed for both anxiety (Friedman Q = 63.32, p < 0.001; Kendall's W = 0.34) and depression (Q = 68.36, p < 0.001; W = 0.37). Mean HADS-A scores increased from 7.40 ± 2.70 at T0 to 9.22 ± 3.35 at T1 and 8.55 ± 2.78 at T2. Mean HADS-D scores increased from 6.53 ± 2.47 to 8.06 ± 3.02 and 8.24 ± 2.41, respectively. Clinically relevant anxiety (HADS-A ≥ 8) increased from 41.7% to 66.3% and 58.7%, while clinically relevant depression (HADS-D ≥ 8) increased from 27.1% to 54.3% and 56.5%. Sensitivity analyses for severe cases (HADS ≥ 11) confirmed consistent temporal trajectories (p < 0.001). Subgroup analyses (sex, indication, age) revealed no significant differences (p > 0.15), and no ICD shocks were delivered during follow-up. Anxiety and depression were strongly correlated at all time points (p < 0.001). Conclusions: Anxiety and depression symptoms are highly prevalent among ICD recipients and follow distinct temporal trajectories during the post-implantation course, with anxiety peaking early and depressive symptoms showing a more sustained increase in the absence of device therapies. Routine psychological screening and stage-specific psychosocial support strategies should be evaluated for integration into standard ICD care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Psychological impact of implantable cardiac devices: reassurance or distress?European Heart Journal · 2026
- Device-related events do not alter long-term psychological distress after implantable cardioverter-defibrillator implantation: A 24-month prospective cohort study.Heart rhythm O2 · 2026
- PSY-ICD study: AI phenotyping identifies device-focused distress overlooked by conventional mood assessment in ICD recipientsEuropean Heart Journal · 2026
- Anxiety, Depressive Symptoms, and Physical Activity During Early Recovery After Cardiac Surgery: A Prospective Cohort Study.Journal of cardiovascular development and disease · 2026
- Preoperative depression or anxiety and late new-onset atrial fibrillation after cardiac surgery: an observational cohort study.European heart journal open · 2026
- Anxiety and depression and secondary prevention of coronary heart disease in 14 countries across six WHO regions: the INTERASPIRE studyEuropean Journal of Preventive Cardiology · 2025