Acoustically Driven Coated Microbubbles in Peristaltic Non-Newtonian Blood Flow: Rupture-Gated Release and Near-Wall Migration
Ahmed K. Abu-Nab, Awatif J. Alqarni, Essam M. Elsaid
Key points
From the paper's conclusion- These results establish frequency–size matching as the primary lever for rupture-gated release and near-wall migration, with the peristaltic amplitude ratio as a geometric modulator of the wall-directed attraction.
Abstract
Ultrasound-driven coated microbubbles are a promising vehicle for targeted drug delivery, yet how peristaltic wall motion, non-Newtonian blood rheology, and shell-resolved bubble dynamics jointly govern delivery remains poorly understood. Resolving this coupling, we identify two operating principles for microbubble-mediated delivery: drug release is gated by shell rupture rather than graded by acoustic amplitude, and near-wall targeting is governed by matching the drive frequency to the shell resonance. At the clinically standard operating point (PA = 120 kPa, f = 2 MHz, mechanical index MI = 0.085) 88% of the payload is released within one acoustic cycle, while the minimum rupture threshold reported here lies below MI = 0.06; for SonoVue-like shells the threshold itself is minimized along the frequency–size locus fopt R0 ≈ 3.9 MHz.μm. We establish these results with a multiscale framework coupling a Carreau–Yasuda peristaltic carrier flow, obtained from a long-wave lubrication reduction, with the Lagrangian dynamics of a coated microbubble governed by the Marmottant–Keller–Miksis equation and a phenomenological rupture-gated release model, integrated with an adaptive stiff solver at acoustic resolution. The rupture threshold, at which the periodic radial orbit first reaches the rupture radius, is mapped in the drive-frequency–pressure plane. Near-wall migration is driven not by the hydrodynamic pressure, which modulates the oscillation by only one part in 105, but by the secondary-Bjerknes attraction: in the continuity-consistent peristaltic carrier field it induces a radial migration of 28% of the vessel radius over three peristaltic periods at the shell resonance of a 1 MHz drive, f shell/f ≈ 1.13, more than an order of magnitude above that of smaller off-resonant bubbles and insensitive to the near-wall regularization. Shear-thinning suppresses the peristaltic pressure variation as S=0.21Cuw−0.48, thirteen-fold at baseline, while reducing the net throughput by only about 10%. These results establish frequency–size matching as the primary lever for rupture-gated release and near-wall migration, with the peristaltic amplitude ratio as a geometric modulator of the wall-directed attraction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microbubbles for Acoustically Mediated Drug Delivery to the Inner EarMolecular Pharmaceutics · 2026
- Microbubble Shell Stiffness Engineering Enhances Ultrasound Imaging, Drug Delivery, and SonoporationAdvanced Materials · 2025
- In vitro targeted microbubble adhesion exhibits a maximum at intermediate acoustic pressuresFrontiers in Acoustics · 2026
- Tuning the Shell Elasticity of Phospholipid-Coated Microbubbles via Palmitic Acid DopingLangmuir · 2025
- Acoustic suppression in polydisperse microbubble populations: a statistical dynamics study coupling shell rupture and size distribution.Ultrasonics · 2026
- Acoustically driven micro/nanobubbles: from fundamental mechanisms to biomedical applications.Microsystems & nanoengineering · 2026