Design of Attack-Resilient Load Frequency Control for Hybrid Wind–Diesel Power Systems Under Hybrid Cyber Attacks
Satheesh Thangavel, Oh-Min Kwon, Sakthivel Rathinasamy, Parthasarathy Velusamy
Key points
From the paper's conclusion- Finally, simulation results are presented to demonstrate the effectiveness and robustness of the developed control scheme under hybrid cyber attacks and multiple disturbances.
Abstract
This paper investigates the finite-time boundedness problem of hybrid wind–diesel power systems through an attack-resilient load frequency control framework in the presence of hybrid cyber attacks and multiple disturbances. The considered disturbances include matched disturbances and mismatched disturbances. To address these challenges, an output-reliant disturbance observer is developed to accurately estimate the matched disturbances, while a dissipative mechanism is employed to attenuate the effects of mismatched disturbances. By utilizing the disturbance estimates and the measured system output, a proportional–integral observer is constructed to estimate the system states. Subsequently, an attack-resilient load frequency controller is designed based on the estimated states and disturbances. Furthermore, multimodal false-data-injection and replay attacks are incorporated into the controller channel to realistically model hybrid cyber threats and enhance controller resilience. Based on Lyapunov stability theory and finite-time stability concepts, sufficient stability conditions are derived in terms of linear matrix inequalities to guarantee finite-time boundedness of the closed-loop system. These conditions also provide a systematic approach for computing the observer and controller gain matrices. Finally, simulation results are presented to demonstrate the effectiveness and robustness of the developed control scheme under hybrid cyber attacks and multiple disturbances.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Load Frequency Control for Markov Jump Wind Power Systems Under Hybrid AttacksInternational Journal of Robust and Nonlinear Control · 2026
- Codesign of Fault Detection Observer and Event‐Triggered Controller for Cyber‐Physical Power System Under DoS AttacksInternational Journal of Adaptive Control and Signal Processing · 2026
- Reachability Analysis for the Impact of Cyber Attacks on Wide-area Control System Considering Wind Power Uncertainty Based on Kron Reduction and ZonotopesCSEE Journal of Power and Energy Systems · 2026
- Adjustable Predefined-Time Sliding-Mode Frequency Control of Microgrids with Hybrid Energy Storage Systems and CyberattacksElectronics · 2026
- Network-based event-triggered security control for cascade switched systems under hybrid attacks.ISA transactions · 2026
- Output‐Feedback Adaptive Fuzzy Inverse Optimal Tracking Control for Hybrid‐Attack‐Affected Nonlinear Cyber‐Physical SystemsInternational Journal of Robust and Nonlinear Control · 2026