Hierarchical Regime-Conditioned Ornstein–Uhlenbeck Monitoring for Thermal Control in Memory Reliability Test Equipment
Seunghwan Song
Key points
From the paper's conclusion- On six fixtures of two models the chart attains the nominal false-alarm rate where the hold level is stable, matches tuned baselines without calibration data, and detects a rack-level limit-cycle oscillation within 0.02 min.
Abstract
Burn-in fixtures for memory packages log the chamber temperature every second, but the logs contain no fault labels, the sensor resolution is comparable to the noise, and normal behaviour depends on both the operating regime and the individual fixture; a regime-blind reconstruction detector flagged 67–73% of its test period. This paper models the hold-phase tracking error as a three-level hierarchy (model, fixture, episode) driven by a regime-indexed Ornstein–Uhlenbeck (OU) process observed irregularly through a quantizer. A grid filter over level and state yields randomized probability-integral-transform (PIT) innovations that are independent standard normal for any quantizer when the hyperparameters are known, so cumulative-sum (CUSUM) charts run at theoretical thresholds; simulation shows the calibration survives parameter estimation. Five results are proved: an alarm-inflation formula for mismatched standardization, moment estimators for the variance components, a Fisher-information bound on the level information surviving quantization, a boundary-crossing lower bound for the cold-start false-alarm probability, and a sampling-interval law under which delay grows with coarse spacing and saturates with fine spacing. On six fixtures of two models the chart attains the nominal false-alarm rate where the hold level is stable, matches tuned baselines without calibration data, and detects a rack-level limit-cycle oscillation within 0.02 min.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Finite-Horizon Reliability-Oriented Synthesis of Cumulative Up/Down-Counter Fault-Confirmation Monitors.Sensors (Basel, Switzerland) · 2026
- Distinguishing Process Change, Instrument Fault and Data-Path Corruption in Streaming Telemetry: A Reference Implementation and BenchmarkarXiv · 2026
- Reliability evaluation of mechanical and electrical equipment based on probability statistical modelEngineering Research Express · 2026
- A heteroskedasticity and autocorrelation consistent test for process noise calibration of Kalman filters in multi-sensor orbit determinationarXiv · 2026
- Moment-Orthogonal Quadratic-Envelope E-Processes for Anytime-Valid Location InferencearXiv · 2026
- On data-driven profile monitoring using memory-type control charts: a sequential change-detection framework for chemical engineering processesChemical Product and Process Modeling · 2026