Preload-Window Design and Experimental Calibration of a Compact Spring-Applied Electromagnetic Brake Under Airgap, Voltage, and Temperature Variations

Sumin Baek, Jongman Lee, Pilkwon Jung, Cheewoo Lee, Seunghun Baek

Key points

From the paper's conclusion
  • For all of them, the as-built window is closed at 10.5 V and 120 °C; a smaller gap or pull-in overexcitation is required.

Abstract

A spring-applied electromagnetic brake develops its friction torque from the same spring preload that the electromagnet must overcome. In a compact automotive actuator, a mass limit, a 9–16 V supply, and coil temperatures up to 120 °C constrain this coupling. The design is formulated as a preload window: a torque-based lower bound and a release-based upper bound on the preload, evaluated over the armature stroke and the voltage, temperature, and air-gap set. The window is computed with a nonlinear magnetic equivalent circuit for a 56 mm brake (0.8 N·m torque target, 0.4 kg mass limit). The analysis leads to a thicker armature (4.0 mm) and a larger friction disc (44 mm), lowering the required preload from 108 N to 76 N. Three prototypes met the torque (0.92 ± 0.03 N·m at 20 °C), mass (353 g), and residual-drag targets. The measured force (182 N) was 45% below the prediction, and release at 120 °C required 11.8 V. Because one force value does not identify the calibration, admissible calibrations are bounded by the pull-in and torque data. For all of them, the as-built window is closed at 10.5 V and 120 °C; a smaller gap or pull-in overexcitation is required.