Materials

Cytocompatibility and Physicochemical Properties of Bioceramic and Resin-Based Root Canal Sealers: A Comparative In Vitro Study

Ayfer Atav, Aysenaz Gunes, Nazlı Ecem Tagrisever, Emre Ovsay, Ayça Bal-Öztürk

Preclinical

Key points

From the paper's conclusion
  • Within the limitations of this in vitro study, bioceramic root canal sealers showed generally higher cell viability under the tested extract conditions and greater alkalizing capacity in distilled water than AH Plus; these findings cannot be directly extrapolated to clinical performance.

Abstract

The biocompatibility and physicochemical stability of root canal sealers are critical determinants of endodontic treatment outcomes. This in vitro study comparatively evaluated the chemical characteristics, pH changes, mass changes, and cytocompatibility of four root canal sealers: AH Plus (epoxy resin-based), C-Root (strontium silicate-based bioceramic), Edge BioCeramic Sealer (EEB), and Edge Endo Thermal Flow (EET) (calcium silicate-based bioceramics). Chemical characterization was performed using attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR). Mass changes and pH were monitored at predetermined intervals over a 28-day period in distilled water (initial pH 6.21). Cytotoxicity was assessed by indirect MTT assay using MC3T3-E1 pre-osteoblast and NIH/3T3 fibroblast cell lines. As the cytotoxicity data were obtained from a single experimental run, they were evaluated descriptively according to the 70% viability threshold of ISO 10993-5. All bioceramic root canal sealers produced sustained alkaline pH values (>11.75) throughout the observation period; carbonate bands detected by ATR-FTIR may be associated with this alkalinity, although FTIR does not directly confirm hydration mechanisms or ion release. AH Plus showed progressive net mass gain, whereas all bioceramic root canal sealers exhibited gradual net mass loss. AH Plus demonstrated the lowest mean cell viability in both cell lines (7.21 ± 0.72% in MC3T3-E1; 8.94 ± 0.60% in NIH/3T3), while EET (tested without thermal activation) showed the highest mean cell viability. Under the tested extract condition (1:1 dilution, 24 h exposure), only EET maintained cell viability above the 70% threshold defined by ISO 10993-5 in both cell lines. Viability differed between the two cell line–medium systems, highlighting the importance of multi-cell-line biocompatibility assessment. As the cytotoxicity data derive from a single experimental run, these findings should be regarded as preliminary. Within the limitations of this in vitro study, bioceramic root canal sealers showed generally higher cell viability under the tested extract conditions and greater alkalizing capacity in distilled water than AH Plus; these findings cannot be directly extrapolated to clinical performance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers