Evaluation of the Reaction to Fire of Historic Scots Pine (Pinus sylvestris L.) from a Historic Building in Poland.
Andrzej Jurecki, Wojciech Grześkowiak, Beata Klimek, Marek Wieruszewski
Faculty of Forestry and Wood Technology, Poznań University of Life Sciences, Wojska Polskiego 28, 60-637 Poznań, Poland. · Faculty of Civil Engineering and Architecture, Lublin University of Technology, 20-618 Lublin, Poland.
Key points
From the paper's conclusion- The material was obtained from a historic building, rather than from a controlled ageing experiment; all historic pine tests came from one structural member, and the reference groups were small and heterogeneous.
Abstract
Assessing historic timber requires separating service history from material variability, surface condition and sampling limitations. This study characterizes Scots pine recovered during renovation of the historic half-timbered residential building at farm no. 5 in Swołowo, Poland, dated to 1869, and compares it with contemporary pine and previously published oak results from the same building. Twenty-four historic-pine tests and four contemporary-reference tests were analysed by mass loss calorimetry at 35 and 50 kW/m2. The study extends earlier work by examining, within one historic-pine dataset, how area-normalized peak and total heat release relate to heat release normalized by initial specimen mass, while placing the results in a shared building-provenance context with published oak data. Mean ignition times of historic series ranged from 31.4 to 65.6 s at 35 kW/m2 and from 12.0 to 19.0 s at 50 kW/m2, versus 48.0 and 12.5 s for the references. Mean peak heat-release rates (pHRRs) were 8.4-32.1% higher in historic pine, whereas heat release per initial specimen mass (Q0) was 7.5-22.5% lower; these opposite directions show that peak intensity and mass-normalized heat contribution are not interchangeable. Area-normalized total heat release (THR) varied in direction. Published historic oak showed consistently lower THR, while its pHRR response depended on surface condition. The material was obtained from a historic building, rather than from a controlled ageing experiment; all historic pine tests came from one structural member, and the reference groups were small and heterogeneous. Two mass-signal discrepancies and incomplete specimen-level anatomical and density data further limit inference. Accordingly, the results do not establish an ageing effect or a fire-reaction classification. Fire-performance assessment of historic timber should consider ignition time, peak heat release and mass-normalized heat release separately, without attributing observed differences to age alone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Flammability and SEM-EDS Characterization of Contemporary, Aged and Charred Oak Wood from Historic Timber Structures.Materials (Basel, Switzerland) · 2026
- Fire-Relevant Thermal Degradation, Solid-Residue Retention and Apparent Kinetics of Norway Spruce (Picea abies) Under Inert and Oxidative AtmospheresFire · 2026
- The Temperature Profiles of Ancient Larch Timber Beams Exposed to Radiant Heat SourceFire · 2026
- Physics-based model for wood charring under the standard temperature–time curveFire Safety Journal · 2026
- Reaction-to-Fire Performance of Steam-Exploded and Suberinic Acids-Bonded Particleboards for Building Façade ApplicationsFire · 2026
- Mapping, characterization and quantification of damage in the conservation of built heritageJournal of Building Pathology and Rehabilitation · 2026