Cyclic Behavior and Failure Modes of Q1100 Ultra-High-Strength Steel Box-Section Beam-Columns with Multiple Weld Repair Histories.
Chengzhong Gui, Lihao Chen, Yanmin Zhang, Yuxin Zhao, Quanhao Dong, Yuehang Zhang
School of Earthquake Engineering and Building Safety, University of Emergency Management, Sanhe 065201, China.
Key points
From the paper's conclusion- In this study, the hysteretic behaviour and failure modes of Q1100 UHSS welded box-section beam-columns with extended flanges were examined experimentally, considering several weld-repair histories and strengthening measures.
Abstract
Welding repair is often unavoidable when steel structures in seismic regions are damaged, yet how it affects the cyclic performance of ultra-high-strength steel (UHSS) members is still not well understood. In this study, the hysteretic behaviour and failure modes of Q1100 UHSS welded box-section beam-columns with extended flanges were examined experimentally, considering several weld-repair histories and strengthening measures. Ten test schemes from the SA, SB and SC series were subjected to a constant axial compression together with quasi-static cyclic lateral loading. The variables covered the number of repair passes (0-3), the repair technique, the axial load ratio (0.057-0.216), the steel grade (Q1100 versus Q345), the boundary restraint and the cross-sectional geometry. The Q1100 specimens failed in a fracture-dominated mode that began in the lower plate/weld region, whereas the Q345 specimen failed by buckling followed by tearing. In the SA and SB series, repeated repair tended to reduce the hysteretic energy dissipation and stiffness and to give asymmetric responses; these trends are consistent with cumulative welding damage, although the damage itself was not characterized. Appropriate strengthening combined with lateral restraint either restored or improved the deformation capacity, and the ultimate drift ratios lay between 2% and 9%. The skeleton curves ranged from an almost linear-elastic shape to an S-shape, depending on ductility, axial load and restraint. Extended flanges improved the lateral resistance, while unequal flange widths produced an asymmetric response. When checked against JGJ/T 483-2020, several Q1100 specimens satisfied the strength criterion but exceeded the in-plane or out-of-plane stability limits, which suggests that stability governed a number of the repaired schemes. No metallographic, hardness, residual-stress or fractographic analysis was carried out, so the damage mechanisms proposed here remain interpretive. Even so, these observations offer preliminary evidence for post-earthquake repair strategies and for design checks of Q1100 UHSS members of the type tested.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Study on Seismic Performance of High‐Strength Steel Frames With Double‐Damage ElementsThe Structural Design of Tall and Special Buildings · 2026
- Tensile performance of rebar welded joints jacketed with SCC and UHPC for repair applicationsEngineering Structures · 2026
- Experimental Study on the Seismic Performance of Exterior RC Beam-Column Joints with U-Shaped Steel-Strengthened BeamsBuildings · 2026
- Experimental Study on Seismic Behavior of Irregular-Shaped Steel-Beam-to-CFST Column Joints with Inclined Internal DiaphragmsBuildings · 2025
- Experimental and numerical investigations of UHPFRC-filled circular steel tubular columns under axial and lateral cyclic loadsScientific Reports · 2026
- Microstructure and mechanical properties of ultra-high strength steel fabricated by dual ultrasonic impact treatment-assisted wire arc additive manufacturingJournal of Materials Research and Technology · 2026