Did Material Properties Contribute to the 1284 Collapse of Beauvais Cathedral? A Comparative Assessment of Stone Masonry, Mortar Behaviour and Structural Vulnerability.
Rubén Rodríguez Elizalde
Higher Polytechnic School of Technology and Science, Camilo José Cela University, C/Castillo de Alarcón, 49, Urbanización Villafranca del Castillo, Villanueva de la Cañada, 28692 Madrid, Spain.
Key points
From the paper's conclusion- The results indicate that the material did not cause the collapse through lack of strength but is compatible with a material contribution through its deformability and its sensitivity to water.
Abstract
The partial collapse of the choir vaults of Beauvais Cathedral in 1284 has been explained through structural and constructional hypotheses, but the role of the materials has never been tested against laboratory data. The objective of this study is to quantify, with a transparent probabilistic framework, whether the properties of the stone and the lime mortar could have contributed to the collapse. Four material-dependent mechanisms are assessed-crushing, differential shortening between coursed masonry and monolithic shafts, time-dependent deformation under eccentric load, and the dependence of the buttressing on stone strength-using a traceable database that combines published tests on chalk representative of the Beauvais stone, data on air lime mortars, the documented geometry of the choir and field measurements of the masonry bond. Uncertainty is propagated through 105 Monte Carlo simulations and expressed as central and characteristic safety factors and reliability indices. The central safety factor of the choir piers against crushing is 4.3 for the dry stone and 2.5 for the saturated stone, far below the margin implicit in earlier analyses. Coursed masonry shortens about 4 to 6 times more than a monolithic shaft in the long term, which, under strain compatibility, concentrates stresses of 2.5 to 5 times the mean value in the shafts. Creep-induced amplification is small in a laterally braced pier but becomes critical if lateral restraint is lost. The results indicate that the material did not cause the collapse through lack of strength but is compatible with a material contribution through its deformability and its sensitivity to water.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mechanical properties of masonry structures in Portugal: proposal of new correlations with the Masonry Quality Index (MQI)Bulletin of Earthquake Engineering · 2026
- Calcarenite-Derived Lime Mortars Without Externally Added Aggregate: Experimental Validation and Implications for Historical Construction TechnologiesHeritage · 2026
- Comparative assessment of image-derived mesh topologies for kinematic limit analysis of irregular masonry with rigid and dissipative elementsMeccanica · 2026
- Crushed Brick Waste–Soil Mixtures for Embankment Applications: A Bimsoil Characterization Using Large-Scale Multistage Shear Tests and Technical ApplicationsRecycling · 2026
- On the role of the lantern in the safety of masonry domes: the case of Nuestra Señora de los Ángeles (Mexico City)Meccanica · 2026
- Moisture impact on compressive strength and deformability of brick masonryScientific Reports · 2026