Effects of Cement Type and Vent Hole Presence on Mass-Based Cement Removal Efficiency and Residual Cement Area in Implant Prostheses.
Ji Un Jang, Kyung Rok Kim, Da Hae Kim, Jung Bo Huh
Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea.
Key points
From the paper's conclusion- This in vitro study evaluated the effects of four commercial luting cement systems and the presence of a vent hole on mass-based cement removal efficiency and residual cement area around implant abutments.
Abstract
Residual cement is an important risk factor for peri-implant complications, and both cement properties and prosthetic design may affect its removal. This in vitro study evaluated the effects of four commercial luting cement systems and the presence of a vent hole on mass-based cement removal efficiency and residual cement area around implant abutments. Eighty zirconia restorations were assigned to eight groups (n = 10) according to cement type and venting condition. Cement removal efficiency was calculated from mass changes, and residual cement area on the buccal, lingual, mesial, and distal surfaces was quantified using ImageJ. HC3 robust factorial analysis showed significant effects of cement type and venting condition and a significant interaction (p = 0.017); after Bonferroni correction, the vented and non-vented conditions differed significantly only for GC FujiCEM II. Linear mixed-effects analysis showed significant effects of cement type, venting condition, and abutment surface, including significant interactions among these factors. Residual cement area was lower in the vented condition for all cements and was generally greater on proximal surfaces. Under the tested in vitro conditions, venting was associated with a higher mass-based index and a lower photographed residual cement area on abutment surfaces, with effects that depended on the cement system and abutment surface. These measurements do not establish improved clinical removal of subgingival excess cement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of luting materials on residual cement around cement-retained implant-supported dental restorations: A systematic review.International journal of oral implantology (Berlin, Germany) · 2026
- Comparison of Glycine Air Polishing and a Rotary Titanium Brush for the Removal of a Surrogate Surface Marker from Implants in Class Ib and IIIb Peri-Implant Defects: An In Vitro Study.Journal of clinical medicine · 2026
- Qualitative Analysis of the Cementation Line of Metal-Ceramic Crowns Luted With Resin Cement: A Clinical Case Report.Case reports in dentistry · 2026
- Comparative Evaluation of the Effects of Different Dentin Desensitization Methods on the Bond Strength of Resin Cements to Dentin: An In Vitro StudyMaterials · 2026
- A Stage-Based Decision Framework to Minimize Excess Cement in Cement-Retained Implant Restorations: A Narrative Review.Clinical, cosmetic and investigational dentistry · 2026
- Assessment techniques for residual cement in cement-retained implant restorations: A systematic review.Medical journal, Armed Forces India · 2026