Materials (Basel, Switzerland)

Tensile Behavior of Pre-Embedded Titanium-Alloy Joints in Filament-Wound Carbon-Fiber Composite Tubes After Low-Temperature Conditioning.

Xiaoyong Liu, Zifei Ma, Siyuan Li, Cheng Guo, Haibo Luo, Jun Wu

Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China.

Key points

From the paper's conclusion
  • This study evaluates the room-temperature axial tensile response of T700 carbon-fiber/TDE86 epoxy tubes containing grooved, internally threaded TC4 titanium-alloy inserts after one programmed low-temperature conditioning cycle and separately examines a small ambient end-enlarged configuration.

Abstract

Pre-embedded metal inserts provide a direct load-introduction path for filament-wound composite tubes without cutting the load-carrying fibers. This study evaluates the room-temperature axial tensile response of T700 carbon-fiber/TDE86 epoxy tubes containing grooved, internally threaded TC4 titanium-alloy inserts after one programmed low-temperature conditioning cycle and separately examines a small ambient end-enlarged configuration. Twenty-one destructive test records were analyzed: nine ambient constant-section ("equal-section") specimens, nine independent equal-section specimens after a 25 → -70 → 25 °C chamber-setpoint cycle followed by 24 h at room temperature, and three ambient end-enlarged specimens. At 1 mm/min, the three cohorts had mean peak loads of 81.39, 81.31, and 88.26 kN and coefficients of variation of 14.04%, 8.70%, and 7.85%, respectively. The -0.07 kN difference between the two independent equal-section cohort means does not establish equivalence or absence of a conditioning effect, and the three-specimen end-enlarged comparison does not isolate a causal geometry effect. Macroscopic failure was dominated by insert pull-out accompanied by visible adhesive/interfacial separation, laminate-layer damage, attached fragments, and local splitting. Because local slip, bond-line deformation, and system compliance were not measured, equilibrium and competing limit states are used only as a qualitative framework. The results concern post-conditioning room-temperature response, not in situ performance at -70 °C.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Tensile Behavior of Pre-Embedded Titanium-Alloy Joints in Filament-Wound Carbon-Fiber Composite Tubes After Low-Temperature Conditioning — Science Skim