Use of Demineralized Autologous Dentin Graft with the Tooth Processing Device in Immediate Post-Extraction Implant Placement and Loading: A 12-Month Evaluation of Peri-Implant Soft Tissue Stability.
Giuseppe Bavetta, Stefano Di Carlo, Giulia Amelina, Francesca De Angelis, Luca Piccoli, Nicola Pranno, Enrico Guerrieri, Edoardo Brauner
Private Practice, Studio Dentistico Associato Bavetta, 90143 Palermo, Italy. · Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy.
Key points
From the paper's conclusion- Conclusions: Within the limitations of this study, immediate implant placement and loading combined with autologous dentin grafting using the Tooth Transformer device resulted in limited peri-implant soft tissue alterations after 12 months.
Abstract
Purpose: To evaluate the effectiveness of immediate implant placement and loading combined with autologous dentin grafting in reducing post-extraction tissue remodelling, with particular emphasis on peri-implant soft tissue stability in the esthetic zone. Materials and Methods: This retrospective observational study included 13 patients (14 implant sites) with Type 1 extraction sockets in the anterior maxilla. Following atraumatic tooth extraction, implants were immediately placed and grafted with autologous dentin processed from the extracted tooth using the Tooth Transformer device. Screw-retained provisional restorations were immediately delivered through a digital workflow, and definitive restorations replicated the provisional transmucosal profile. Soft tissue dimensional changes were evaluated by superimposing stereolithography (STL) files from intraoral scans acquired before treatment and after at least 12 months. Vertical changes were measured as a single value, while horizontal changes were assessed 2 and 4 mm apical to the gingival margin. Results: All implants remained clinically stable, with no biological or prosthetic complications. Mean vertical soft tissue collapse was 0.69 mm, while mean horizontal collapse was 0.71 mm at 2 mm and 0.57 mm at 4 mm apical to the gingival margin. In most cases, dimensional changes were below 1 mm, with greater contour alterations at the more coronal level. Conclusions: Within the limitations of this study, immediate implant placement and loading combined with autologous dentin grafting using the Tooth Transformer device resulted in limited peri-implant soft tissue alterations after 12 months. This protocol may represent a biologically favourable, minimally invasive approach for ridge preservation while avoiding donor site morbidity and heterologous grafting materials.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Autologous Tooth-Shell Technique for Ridge Reconstruction and Immediate Implant Placement: A Two-Case Technical Report and Review of the Literature.Journal of functional biomaterials · 2026
- Effect of Crestal Soft-Tissue Augmentation Prior to or Simultaneously With Implant Placement on Peri-Implant Tissue Dimensions: Histological Outcomes of an Experimental In Vivo Study.Journal of clinical periodontology · 2026
- Influence of acellular dermal matrix on peri-implant soft tissue phenotype and marginal bone loss following immediate implant placement in the anterior maxilla: a randomized controlled clinical trial.BMC oral health · 2026
- Alveolar Ridge Preservation Comparing Healing Outcomes of Two Different Putty Grafts: A Clinical and Histologic Study.The International journal of periodontics & restorative dentistry · 2026
- Tooth Root-Derived Graft Promotes Complete Bone Replacement in Alveolar Ridge Preservation: Comparative Study with a Collagenic Xenograft in DogsJournal of Functional Biomaterials · 2026
- Effect of immediate implant placement on buccal bone stability in fresh extraction sockets: A prospective study.Bioinformation · 2026