Concentrated Load Capacity of Prestressed Hollow Core Floors: Research Based on Full-Scale Experimental Investigation.
Miłosz Jeziorski, Wit Derkowski
Consolis Group Technology Development Centre, 90-527 Lodz, Poland. · Chair of Reinforced Concrete and Prestressed Concrete Structures, Krakow University of Technology, 31-155 Krakow, Poland.
Key points
From the paper's conclusion- Interaction between adjacent units and tying systems increased the load capacity relative to isolated elements; however, the magnitude of this enhancement depended on the specimen and load location, with enhancement ratios ranging from 1.09 to 1.49 at edge positions and from 2.03 to 2.51 at central positions.
Abstract
The geometry of precast prestressed hollow-core cross-sections, production-induced variability in thin-walled concrete properties, and the use of exclusively longitudinal strands as reinforcement present challenges in designing hollow-core floors under concentrated loads. These loads induce complex stress states in webs and flanges, largely governed by concrete tensile strength. While individual hollow-core units have been widely studied, experimental data on full floor systems remain limited despite their expected higher load capacity. To address this gap, an experimental program was conducted on single elements and full floor systems subjected to concentrated loads up to failure. Clear differences in behavior were observed. Single elements exhibited ductile failure governed by shear and flexure, whereas full floor systems failed in a brittle manner dominated by torsional and transverse effects. Interaction between adjacent units and tying systems increased the load capacity relative to isolated elements; however, the magnitude of this enhancement depended on the specimen and load location, with enhancement ratios ranging from 1.09 to 1.49 at edge positions and from 2.03 to 2.51 at central positions. Despite the brittle failure modes, the structural integrity was preserved. Differences were also found between material properties obtained from standard-sized and drilled core specimens. Nevertheless, numerical models based on standard specimen properties showed good agreement with experiments and were not significantly affected by variations in tensile strength, indicating that full floor systems are less sensitive to concrete tensile strength than single elements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Theoretical Analysis of Circular Hollow Steel-Reinforced Concrete Members Under Pure BendingBuildings · 2026
- Comparative Study on Shear Reinforcement Performance of Prestressed Concrete Hollow Slab Beams in Existing HighwaysEngineering Reports · 2026
- Experimental Study and Finite Element Analysis on Load-Bearing Performance of Corrugated Steel-Concrete Composite Arch Structures.Materials (Basel, Switzerland) · 2026
- Finite Element Analysis and Parametric Investigation of Hollow‐Core Composite Columns With Steel and FRP ConfinementAdvances in Civil Engineering · 2026
- Inelastic Flexural Behaviour and Ductility Characteristics of Steel-Encased Composite Beams Incorporating Normal and High-Strength Concrete Under Out-of-Plane Actions: Nonlinear Finite Element InvestigationCivil and Environmental Engineering · 2026
- Experimental and Theoretical Investigations of the Shear Resistance of SCS Composite Structures with Web OpeningsJournal of Structural Engineering · 2025