Materials (Basel, Switzerland)

Experimental Study on the Mechanical Performance of Large Plate Girders Under Eccentric Loading.

Yuxiang Zhang, Xiufeng Chen, Jinli Wei, Ju Chen

School of Intelligent Transportation and Vehicle, Qingdao University of Technology, 777 Jialingjiang Road, Huangdao District, Qingdao 266520, China. · College of Civil Engineering and Architecture, Zhejiang University, 866 Yuhangtang Road, Xihu District, Hangzhou 310058, China.

Key points

From the paper's conclusion
  • To investigate the mechanical performance of large plate girders used in boiler-supporting steel structures under eccentric loading, nine 1:5-scaled closed-section HK-type and open-section π-type specimens were designed and tested.

Abstract

To investigate the mechanical performance of large plate girders used in boiler-supporting steel structures under eccentric loading, nine 1:5-scaled closed-section HK-type and open-section π-type specimens were designed and tested. The specimens had a span of 5960 mm, an overall length of 6220 mm, and a depth of 1760 mm. Concentric loading and eccentric loading with eccentricities of 30 mm, 60 mm, and 90 mm were considered. The results show that under eccentric loading, the mid-span displacement increased with increasing eccentricity for both HK-type and π-type specimens. Compared with π-type specimens, HK-type specimens exhibited smaller mid-span displacements and higher secant stiffness under the same eccentric loading conditions, indicating better deformation resistance. At a load level of 3000 kN, the secant stiffness of the HK-type specimen decreased from 192.31 kN/mm to 172.81 kN/mm as the eccentricity increased from 0 mm to 90 mm, while that of the π-type specimen decreased from 156.57 kN/mm to 142.18 kN/mm. The measured transverse brace stresses of π-type specimens were higher than those of HK-type specimens, indicating stronger interaction between the π-type girder and the lateral-restraint system under the applied eccentric-loading conditions. Under the adopted eccentric loading and lateral restraint conditions, the HK-type specimens exhibited smaller mid-span displacements, higher absolute secant stiffness, and lower transverse-brace stresses than the corresponding π-type specimens. This study provides experimental data for understanding the deformation behavior, torsional response, and stiffness degradation of large plate girders in boiler-supporting steel structures.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers